نتایج جستجو برای: locking plate

تعداد نتایج: 83531  

2015
Leonard Grünwald Stephan Döbele Dankward Höntzsch Theddy Slongo Ulrich Stöckle Thomas Freude Steffen Schröter

Correction of complex deformities is a challenging procedure. Long-term wearing of a fixator after correction and lengthening are inconvenient and has a high rate of complication. The goals of the surgical treatment in the presented case were: (1) correction of the deformity and lengthening of the left leg by the Taylor spatial frame (TSF, Smith and Nephew, Marl, Germany); (2) reduction in the ...

2000
Robert McCaffrey Maureen D. Long Chris Goldfinger Peter C. Zwick John L. Nabelek Cheryl K. Johnson Curt Smith

Global Positioning System vectors and surface tilt rates are inverted simultaneously for the rotation of western Oregon and plate locking on the southern Cascadia subduction thrust fault. Plate locking appears to be largely offshore, consistent with earlier studies, and is sufficient to allow occasional great earthquakes inferred from geology. Clockwise rotation of most of Oregon about a nearby...

2015
M.A Rashid M Parnell W.S Khan A Khan

First metatarsalphalangeal joint arthrodesis is a well established and successful treatment; however there still remains controversy over the best choice of construct. We performed a retrospective study of patients undergoing first metatarsalphalangeal fusion over eighteen months (n=52) using either dorsal non-locking plate with additional compression lag screw fixation or dorsal non-locking pl...

2016
Allison K. Tetreault Brian J. McGrory

BACKGROUND Fixation of the greater trochanter with total hip replacement is challenging and associated with short- and long-term complications. Locking plate technology has been used for fixation of other bones and may be applied successfully in trochanteric fixation. The purpose of this retrospective study was to analyze the utility of the use of trochanteric locking plates in total hip arthro...

Journal: :Danish medical journal 2012
Karl Tobias Haak Henrik Palm Kim Holck Michael Krasheninnikoff Peter Gebuhr Anders Troelsen

INTRODUCTION Immediate weight-bearing following osteosynthesis of proximal tibial fractures is traditionally not allowed due to fear of articular fracture collapse. Anatomically shaped locking plates with sub-articular screws could improve stability and allow greater loading forces. The purpose of this study was to investigate if immediate weight-bearing can be allowed following locking plate o...

2016
Christopher Ioannou Matthew Knight Luca Daniele Lee Flueckiger Ezekiel S L Tan

BACKGROUND The objective of this study is to analyse the effectiveness of the surgical torque limiter during operative use. The study also investigates the potential differences in torque between hand and drill-based screw insertion into locking plates using a standardised torque limiter. METHODS Torque for both hand and power screw insertion was measured through a load cell, registering 6.66...

Journal: :Orthopedics 2012
Scott D Pennington Xavier A Duralde

Locking plates are increasingly used to surgically treat proximal humerus fractures. Knowledge of the bone quality of the proximal humerus is important. Studies have shown the medial and dorsal aspects of the proximal humeral head to have the highest bone strength, and this should be exploited by fixation techniques, particularly in elderly patients with osteoporosis. The goals of surgery for p...

Journal: :Acta orthopaedica Belgica 2013
Jun-Feng Cai Feng Yuan Min Ma Wei Zhou Shu-Lin Luo Feng Yin

We describe our experience with a two-incision anterolateral acromial approach in locking plate fixation of proximal humeral fractures in older adults. Mean time between injury and surgery was 3.08 +/- 1.24 days. A proximal anterolateral transverse incision and a more distal longitudinal incision were used. A locking plate was inserted along the lateral side of the humerus from the proximal inc...

2012
M. Sadeh Y. Hamiel A. Ziv Y. Bock P. Fang S. Wdowinski

[1] Large-scale crustal deformation in the Levant is mainly related to the DST and the CFS. The former is an active left lateral transform, bounding the Arabian plate and the Sinai sub-plate, and the latter branches out of the former and separates the Sinai sub-plate into two tectonic domains. In this study we obtain the velocities of 33 permanent GPS stations and 145 survey stations that were ...

2013
R. K. Singh Sharad Chand U. S. Pal Sanjib K. Das V. P. Sinha

AIM The purpose of this study was to determine and compare various postoperative parameters like ease of operability, plate adaptability, stability etc., associated with use of matrix miniplate versus locking miniplate in the treatment of displaced mandibular angle fractures. MATERIALS AND METHODS The study was carried out in the Department of Oral and Maxillofacial surgery, King George's Med...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید