نتایج جستجو برای: low energy electrons multicellular model geant4 dna

تعداد نتایج: 4003989  

2011
M. H. F. Bettega V. McKoy A. A. Noyes M. A. Khakoo

We report measured and calculated cross sections for elastic scattering of low-energy electrons by isopropanol (propan-2-ol). The experimental data were obtained using the relative flow technique with helium as the standard gas and a thin aperture as the collimating target gas source, which permits use of this method without the restrictions imposed by the relative flow pressure conditions on h...

Journal: :Physics in medicine and biology 2016
Lucas Burigo Igor Pshenichnov Igor Mishustin Gerhard Hilgers Marcus Bleicher

The Geant4-based Monte Carlo model for Heavy-Ion Therapy (MCHIT) was extended to study the patterns of energy deposition at sub-micrometer distance from individual ion tracks. Dose distributions for low-energy (1)H, (4)He, (12)C and (16)O ions measured in several experiments are well described by the model in a broad range of radial distances, from 0.5 to 3000 nm. Despite the fact that such dis...

Journal: :Journal of Physics: Conference Series 2009

2001
K. Bodek T. Boehm D. Conti N. Danneberg W. Fetscher C. Hilbes M. Janousch St. Kistryn K. K . ohler J. Lang M. Markiewicz J. Sromicki J. Zejma

Amultiwire proportional chamber has been developed to study the properties of a detector for tracking of low energy electrons (0.2–1 MeV). The geometry and the materials used have been optimized to minimize energy losses and multiple Coulomb scattering. The detector is equipped with a special electronic readout and event selection system, consisting of an amplifier=comparator stage, a fast trig...

Elham Kashian Hadi Taleshi Ahangari Mohammad Ali Tajik Mansoury Peyman Hejazi, Sayyed Bijan Jia, Shiva Zarifi

Introduction: GATE (Geant4 Application for Tomographic Emission) is a Monte Carlo simulation platform developed by the OpenGATE collaboration since 2001 and first publicly released in 2004. In Geant4, each physics process is described by a model (several models are sometimes available for a given physics process) and a corresponding cross-section table. All Geant4 physics model...

2008
F. Wauters

The performance of a Si PIN diode (type Hamamatsu S3590-06) as an energy sensitive detector operating at cryogenic temperatures (∼10 K) and in magnetic fields up to 11 T was investigated, using a Bi conversion electron source. It was found that the detector still performs well under these conditions, with small changes in the response function being observed in high magnetic fields, e.g. a 30% ...

E’tesam Malekzadeh Hossain Rajabi

Introduction: Theranostics, in particular, the use of radionuclides with the capability of simultaneous imaging and treatment has opened new horizons in personalized treatment planning of targeted radiation therapy. In this approach, positive beta or gamma emitters are required for imaging and alpha, beta and Auger electrons for treatment purpose. On the other hand, studies hav...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید