نتایج جستجو برای: myocardial perfusion spect

تعداد نتایج: 202687  

Journal: :Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance 2006
Jolanta Misko Mirosław Dziuk Ewa Skrobowska Norbert Szalus Jacek Pietrzykowski Agnieszka Warczynska

PURPOSE Myocardial perfusion is routinely measured by SPECT--this technique has a rather low spatial resolution but covers the whole myocardium and is equipped with efficient image analysis software. Cardiac MRI has higher spatial resolution than SPECT and excellent sequences for myocardial function and viability detection but the lack of easy-to-use methods of acquisition and post-processing o...

Journal: :Journal of the American College of Cardiology 1997
J J Mahmarian L A Moyé G A Nasser S F Nagueh M F Bloom N L Benowitz M S Verani W G Byrd C M Pratt

OBJECTIVES We sought to determine the effects of nicotine patch therapy, when used to promote smoking cessation, on myocardial ischemia in patients with coronary artery disease. BACKGROUND Nicotine patches substantially increase quit rates among cigarette smokers, but their safety in patients with myocardial ischemia who are attempting to quit smoking is unknown. METHODS This is a prospecti...

Journal: :Cardiovascular Ultrasound 2009
Petri Gudmundsson Kambiz Shahgaldi Reidar Winter Magnus Dencker Mariusz Kitlinski Ola Thorsson Lennart Ljunggren Ronnie B Willenheimer

BACKGROUND Real-time perfusion (RTP) contrast echocardiography can be used during adenosine stress echocardiography (ASE) to evaluate myocardial ischemia. We compared two different types of RTP power modulation techniques, angiomode (AM) and high-resolution grayscale (HR), with 99mTc-tetrofosmin single-photon emission computed tomography (SPECT) for the detection of myocardial ischemia. METHO...

Journal: :iranian journal of nuclear medicine 2008
vahid reza dabbagh kakhki seyed rasoul zakavi ramin sadeghi mahdi reza emadzadeh amirhosein vejdani

introduction: although left ventricular(lv) function parameters measured by gated myocardial perfusion spect (gspect) have been validated, experimental data have revealed that the calculated the lv function parameters using gspect are affected by patient populations as well as particular acquisition and processing conditions. we tried to determine the normal values of gspect in an iranian popul...

Journal: :Clinical physiology and functional imaging 2006
Petri Gudmundsson R Winter M Dencker M Kitlinski O Thorsson L Ljunggren R Willenheimer

BACKGROUND Real-time perfusion (RTP) contrast echocardiography using low mechanical index power modulation technique allows for simultaneous myocardial perfusion and wall motion analysis. RTP-adenosine stress echocardiography (ASE) could be an alternative to dobutamine-atropine stress echocardiography; more tolerable for the patients and possibly similarly accurate. We aimed to evaluate RTP-ASE...

Journal: :Circulation 1989
J K Kahn I McGhie M S Akers M N Sills T L Faber P V Kulkarni J T Willerson J R Corbett

We tested the hypothesis that 99mTc 2-methoxy-isobutyl-isonitrile (99mTc MIBI), a new radiopharmaceutical for myocardial perfusion imaging, provides accurate noninvasive detection of coronary artery disease (CAD). Imaging in patients after exercise and at rest with 99mTc MIBI was compared with imaging after exercise and redistribution with 201Tl in 12 normal subjects and 38 patients with angiog...

2017
Kenichi Nakajima Shinichiro Kumita Yoshio Ishida Mitsuru Momose Jun Hashimoto Koichi Morita Junichi Taki Shohei Yamashina Hirotaka Maruno Masami Ogawa Masahiro Kubota Munehiro Takahashi Tetsuro Odagawa Koichi Yokozuka

Introduction Myocardial SPECT has been utilized as an important tool for optimal decision making in cardiology. The Guidelines for the Clinical Use of Cardiac Radionuclide Imaging were originally published in 1986 in the USA and updated in 1995. 1 In Japan, Nuclear Cardiology Guidelines were also summarized and published in 2005 by the task force of the Japan Circulation Society, Japanese Socie...

2011
Neil Maredia John P Greenwood Catherine Dickinson Aleksandra Radjenovic Stephen G Ball Sven Plein

Background First pass myocardial perfusion imaging by CMR may permit the detection of myocardial ischaemia with greater accuracy than single photon emission computed tomography (SPECT). Technical developments have led to improvements in myocardial perfusion CMR, particularly through accelerated data acquisition methods. These permit the acquisition of data at higher spatial resolution than conv...

Introduction: Asymptomatic diabetic patients are at increased risk of cardiovascular complications. Myocardial perfusion scan may be effective in risk evaluation in this population. Methods: 106 asymptomatic diabetic patients (age: min: 37, max: 82, mean: 57.73±8.88), including 56 females (52.8%) and 50 males (47.2%) were enrolled in the study. Myocardial perfusion scintigraphy was performed b...

2016
William E. Moody Erica L.S. Lin Matthew Stoodley David McNulty Louise E. Thomson Daniel S. Berman Nicola C. Edwards Benjamin Holloway Charles J. Ferro Jonathan N. Townend Richard P. Steeds

Coronary artery calcium score (CACS) is a strong predictor of adverse cardiovascular events in the general population. Recent data confirm the prognostic utility of single-photon emission computed tomographic (SPECT) imaging in end-stage renal disease, but whether performing CACS as part of hybrid imaging improves risk prediction in this population is unclear. Consecutive patients (n = 284) wer...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید