نتایج جستجو برای: myocatrdial persfuion imaging mpi

تعداد نتایج: 464574  

2013
Daniel S. Berman Raymond Taillefer Gajanan Bhat

Objectives This was a phase II trial to assess flurpiridaz F 18 for safety and compare its diagnostic performance for positron emission tomography (PET) myocardial perfusion imaging (MPI) with Tc-99m single-photon emission computed tomography (SPECT) MPI with regard to image quality, interpretative certainty, defect magnitude, and detection of coronary artery disease (CAD) ( 50% stenosis) on in...

Journal: :Journal of the American College of Cardiology 2007
Louise D Metz Mary Beattie Robert Hom Rita F Redberg Deborah Grady Kirsten E Fleischmann

OBJECTIVES The purpose of this work was to determine the prognostic value of normal exercise myocardial perfusion imaging (MPI) tests and exercise echocardiography tests, and to determine the prognostic value of these imaging modalities in women and men. BACKGROUND Exercise MPI and exercise echocardiography provide prognostic information that is useful in the risk stratification of patients w...

2016
Jan Sedlacik Andreas Frölich Johanna Spallek Nils D Forkert Tobias D Faizy Franziska Werner Tobias Knopp Dieter Krause Jens Fiehler Jan-Hendrik Buhk

PURPOSE The purpose of this work was to demonstrate the capability of magnetic particle imaging (MPI) to assess the hemodynamics in a realistic 3D aneurysm model obtained by additive manufacturing. MPI was compared with magnetic resonance imaging (MRI) and dynamic digital subtraction angiography (DSA). MATERIALS AND METHODS The aneurysm model was of saccular morphology (7 mm dome height, 5 mm...

Journal: :Journal of the American College of Cardiology 2010
Robert C Hendel Manuel Cerqueira Pamela S Douglas Karen C Caruth Joseph M Allen Neil C Jensen Wenqin Pan Ralph Brindis Michael Wolk

OBJECTIVES The aim of this study was to assess the feasibility of evaluation for appropriate use of radionuclide myocardial perfusion imaging (MPI) in multiple clinical sites and to determine use patterns as well as identify areas of apparent inappropriate use. BACKGROUND Although cardiac imaging is highly valued for decision-making, the growth and expense related to these procedures has rais...

Journal: :Acta Cardiologica Sinica 2016
Pei-Ying Hsu Wen-Jeng Lee Mei-Fang Cheng Ruoh-Fang Yen Kai-Yuan Tzen Yen-Wen Wu

PURPOSE Several studies have suggested that a combined approach of stress myocardial perfusion imaging (MPI) and coronary computed tomography angiography (CCTA) can provide diagnostic results with excellent accuracy. We aimed to explore whether the addition of CCTA to stress MPI provides incremental diagnostic value in intermediate-to-high cardiovascular risk patients. METHODS A total of 106 ...

2017
Sarah Vaalma Jürgen Rahmer Nikolaos Panagiotopoulos Robert L Duschka Jörn Borgert Jörg Barkhausen Florian M Vogt Julian Haegele

Magnetic Particle Imaging (MPI) is able to provide high temporal and good spatial resolution, high signal-to-noise ratio and sensitivity. Furthermore, it is a truly quantitative method as its signal strength is proportional to the concentration of its tracer, superparamagnetic iron oxide nanoparticles (SPIOs). Because of that, MPI is proposed to be a promising future method for cardiovascular i...

Journal: :Hellenic journal of nuclear medicine 2015
Jian-Wei Yuan Yue-Tao Wang Cun-Zhi Lu

OBJECTIVE Anatomic coronary artery disease (CAD) can be determined by coronary angiography (CAG) in patients with normal stress single photon emission tomography (SPET) myocardial perfusion imaging (MPI). Coronary angiography results of patients with negative exercise MPI and the prognosis of these patients (CAG-diagnosed CAD vs. non-CAD) were investigated in the current study. SUBJECTS AND M...

Journal: :Biomedical Signal Processing and Control 2021

Magnetic particle imaging (MPI) is an emerging medical modality that based on the non-linear response of magnetic nanoparticles. The reconstruction task inverse problem and ill-posed in nature. results state-of-the-art regularization model have many artifacts, time resolution should be improved significantly for real-time imaging. To this end, we first propose to use elastic net (EN) MPI recons...

Journal: :Circulation. Cardiovascular imaging 2013
Wael A AlJaroudi M Chadi Alraies Oussama Wazni Manuel D Cerqueira Wael A Jaber

BACKGROUND American College of Cardiology/American Heart Association appropriate use criteria recommend performing stress myocardial perfusion imaging (MPI) for intermediate- to high-risk patients presenting with syncope but not for low-risk patients. However, there are limited data to support these recommendations. We investigated the yield of stress MPI for the evaluation of syncope in patien...

Journal: :Journal of the American College of Cardiology 2008
Raymond J Gibbons Todd D Miller David Hodge Lynn Urban Philip A Araoz Patricia Pellikka Robert B McCully

OBJECTIVES The purpose of this study was to apply published appropriateness criteria for single-photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI) in a single academic medical center. BACKGROUND The American College of Cardiology Foundation (ACCF) and the American Society of Nuclear Cardiology (ASNC) have developed appropriateness criteria for stress SPECT MPI to a...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید