نتایج جستجو برای: orthopaedic implant

تعداد نتایج: 58414  

2016
Sunil Kumar Dinesh Kumar S.P.S. Gill Pulkesh Singh Manish Raj Alok Gupta

Background: Variety of implant design and quality are available and being used by orthopaedic surgeon to restore anatomy and enhance healing process of fractured bone. At times implants fail to achieve desired out come in few cases and a repeat surgery is required. This study evaluates causes of implant failure in fracture long bones. Methods: Retrospective study analyzing 53 patients with 66 l...

Journal: :Materials science & engineering. C, Materials for biological applications 2016
Sankalp Agarwal James Curtin Brendan Duffy Swarna Jaiswal

Magnesium (Mg) and its alloys have been extensively explored as potential biodegradable implant materials for orthopaedic applications (e.g. Fracture fixation). However, the rapid corrosion of Mg based alloys in physiological conditions has delayed their introduction for therapeutic applications to date. The present review focuses on corrosion, biocompatibility and surface modifications of biod...

Journal: :Bulletin (Hospital for Joint Diseases (New York, N.Y.)) 2001
L M Specht K J Koval

These are just a few representative applications of the synergistic use of computer and robotic technology assisting the orthopaedic surgeon. While the individual systems are certain to change over time, the basic principles of correlating radiographic and anatomic data through a registration process, and displaying additional instrument or implant information through smart tools and surgical n...

2015
Thomas P. Sollecito

Background. A panel of experts (the 2014 Panel) convened by the American Dental Association Council on Scientific Affairs developed an evidence-based clinical practice guideline (CPG) on the use of prophylactic antibiotics in patients with prosthetic joints who are undergoing dental procedures. This CPG is intended to clarify the “Prevention of Orthopaedic Implant Infection in Patients Undergoi...

Journal: :Journal of orthopaedic trauma 2004
Mark B Sommers Christoph Roth H Hall Benjamin C C Kam Larry W Ehmke James C Krieg Steven M Madey Michael Bottlang

OBJECTIVES To establish a laboratory model of implant cutout, which can evaluate the effect of implant design on cutout resistance in a clinically realistic "worst case" scenario. SETTING Orthopaedic biomechanics laboratory. DESIGN Implant cutout was simulated in an unstable pertrochanteric fracture model, which accounted for dynamic loading, osteoporotic bone, and a defined implant offset....

Journal: :Journal of orthopaedic research : official publication of the Orthopaedic Research Society 2018
Noel Conlisk Colin R Howie Pankaj Pankaj

Motion at the bone-implant interface, following primary or revision knee arthroplasty, can be detrimental to the long-term survival of the implant. This study employs experimentally verified computational models of the distal femur to characterize the relative motion at the bone-implant interface for three different implant types; a posterior stabilizing implant (PS), a total stabilizing implan...

Journal: :Biomaterials 2016
Jordan Raphel Mark Holodniy Stuart B Goodman Sarah C Heilshorn

The two leading causes of failure for joint arthroplasty prostheses are aseptic loosening and periprosthetic joint infection. With the number of primary and revision joint replacement surgeries on the rise, strategies to mitigate these failure modes have become increasingly important. Much of the recent work in this field has focused on the design of coatings either to prevent infection while i...

2016
S. A. Brennan C. Ní Fhoghlú B. M. Devitt F. J. O’ Mahony D. Brabazon A. Walsh

From Our Lady of Lourdes Hospital, Drogheda, Ireland Implant-associated infection is a major source of morbidity in orthopaedic surgery. There has been extensive research into the development of materials that prevent biofilm formation, and hence, reduce the risk of infection. Silver nanoparticle technology is receiving much interest in the field of orthopaedics for its antimicrobial properties...

Journal: :The Journal of bone and joint surgery. British volume 2010
J J Guo N Tang H L Yang T S Tang

We compared the outcome of closed intramedullary nailing with minimally invasive plate osteosynthesis using a percutaneous locked compression plate in patients with a distal metaphyseal fracture in a prospective study. A total of 85 patients were randomised to operative stabilisation either by a closed intramedullary nail (44) or by minimally invasive osteosynthesis with a compression plate (41...

2017
Carolina Micolini Frederick Benjamin Holness James A. Johnson Aaron David Price

Load transfer through orthopaedic joint implants is poorly understood. The longer-term outcomes of these implants are just starting to be studied, making it imperative to monitor contact loads across the entire joint implant interface to elucidate the force transmission and distribution mechanisms exhibited by these implants in service. This study proposes and demonstrates the design, implement...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید