نتایج جستجو برای: patient specific qa

تعداد نتایج: 1683295  

Journal: :The Journal of Experimental Medicine 1987
G L Waneck D H Sherman S Calvin H Allen R A Flavell

We screened a cDNA library prepared from a BALB.B10 CTL clone that expresses Qa-2 antigen, and isolated four clones derived from Q7b, a Qa region gene of C57BL/10. One of these Q7b cDNAs and the Q7b chromosomal gene were subcloned into expression vectors and transfected into L cells and R1.1 thymoma cells. We found that the chromosomal Q7b gene expresses Qa-2 on the surface of R1.1 cells, but n...

2016
Xiaohua Wang Jintao Zhang David J. Baylink Chih-Huang Li Douglas M. Watts Yi Xu Xuezhong Qin Michael H. Walter Xiaolei Tang

Qa-1 epitopes, the peptides that bind to non-classical major histocompatibility complex Ib Qa-1 molecules and are recognized by Qa-1-restricted CD8+ regulatory T (Treg) cells, have been identified in pathogenic autoimmune cells that attack myelin sheath in experimental autoimmune encephalomyelitis (EAE, an animal model for multiple sclerosis [MS]). Additionally, immunization with such epitopes ...

2016
Nobutaka Mukumoto Mitsuhiro Nakamura Masahiro Yamada Kunio Takahashi Mami Akimoto Yuki Miyabe Kenji Yokota Shuji Kaneko Akira Nakamura Satoshi Itasaka Yukinori Matsuo Takashi Mizowaki Masaki Kokubo Masahiro Hiraoka

PURPOSE The purposes of this study were two-fold: first, to develop a four-axis moving phantom for patient-specific quality assurance (QA) in surrogate signal-based dynamic tumor-tracking intensity-modulated radiotherapy (DTT-IMRT), and second, to evaluate the accuracy of the moving phantom and perform patient-specific dosimetric QA of the surrogate signal-based DTT-IMRT. METHODS The four-axi...

2015
Dewayne L. Defoor Luis A. Vazquez‐Quino Panayiotis Mavroidis Nikos Papanikolaou Sotirios Stathakis

In this project, we investigated the use of an electronic portal imaging device (EPID), together with the treatment planning system (TPS) and MLC log files, to determine the delivered doses to the patient and evaluate the agreement between the treatment plan and the delivered dose distribution. The QA analysis results are presented for 15 VMAT patients using the EPID measurements, the ScandiDos...

Journal: :Medical physics 2013
Ramon Alfredo C Siochi Andrea Molineu Colin G Orton

Suggestions for topics suitable for these Point/Counterpoint debates should be addressed to Colin G. Orton, Professor Emeritus, Wayne State University, Detroit: [email protected]. Persons participating in Point/Counterpoint discussions are selected for their knowledge and communicative skill. Their positions for or against a proposition may or may not reflect their personal opinions or the pos...

Journal: :Ultrasound in medicine & biology 2000
E L Madsen

In 1992, the American College of Radiology (ACR) recommended a specific phantom and image analysis procedure for (x-ray) mammography (American College of Radiology 1992). This event removed uncertainty in the USA regarding quality assurance (QA) in mammography. Although the phantom and analysis procedure are probably not ideal, existence of definitive recommendations has resulted in essentially...

2013
Thuc Pham Jianjie Luo

The Delta4 3D dose verification device was commissioned in the current work for pre-treatment quality assurance (QA) of Intensity Modulated Radiotherapy (IMRT) and Volumetric Modulated Arc Therapy (VMAT) plans. The cross calibration and relative array calibration were performed to enable absolute dose comparison. The linearity of response with dose and temperature sensitivity tests were also co...

Journal: :Medical physics 2013
E McKenzie P Balter J Jones D Followill F Stingo S Kry

PURPOSE To analyze the reproducibility of patient specific IMRT QA results across five different clinical devices and one in-house detector by quantifying variations in the QA results from delivery-to-delivery (without re-setup, "redelivery") and variations when set-up is repeated ("re-setup"). METHODS Six patient plans were selected from among four treatment sites. Six methods of IMRT QA wer...

Journal: :International journal of medical physics, clinical engineering and radiation oncology 2017
Maria F Chan Chin-Cheng Chen Chengyu Shi Jingdong Li Xiaoli Tang Xiang Li Dennis Mah

Radiochromic film for spot-scanning QA provides high spatial resolution and efficiency gains from one-shot irradiation for multiple depths. However, calibration can be a tedious procedure which may limit widespread use. Moreover, since there may be an energy dependence, which manifests as a depth dependence, this may require additional measurements for each patient. We present a one-scan protoc...

2016
Jung‐in Kim Jin‐Beom Chung Ju‐Young Song Sung Kyu Kim Yunseok Choi Chang Heon Choi Won Hoon Choi Byungchul Cho Jin Sung Kim Sung Jin Kim Sung‐Joon Ye

This study aims to investigate tolerance levels for patient-specific IMRT dose QA (DQA) using the confidence limits (CL) determined by a multi-institutional study. Eleven institutions participated in the multi-institutional study in Korea. A total of 155 DQA measurements, consisting of point-dose differences (high- and low-dose regions) and gamma passing rates (composite and per-field) for IMRT...