M. Allahverdi, M.H. Zahmatkesh, M.R. Ay, N. Riyahi Alam, T. Allahverdi Pourfallah,

Background: Polymer gel dosimetry is still the only dosimetry method for direct measuring of threedimensional dose distributions. MRI Polymer gel dosimeters are tissue equivalent and can act as a phantom material. In this study the obtained isodose maps with PAGAT polymer gel dosimeter were compared to those calculated with EGSnrs for singleshot irradiations of 8 and 18 mm collimators of...

Journal: :journal of biomedical physics and engineering 0
m t bahreyni toossi medical physics research center, faculty of medicine, mashhad university of medical sciences, mashhad, iran f khorshidi medical physics research center, faculty of medicine, mashhad university of medical sciences, mashhad, iranسازمان اصلی تایید شده: دانشگاه علوم پزشکی مشهد (mashhad university of medical sciences) m ghorbani medical physics research center, faculty of medicine, mashhad university of medical sciences, mashhad, iranسازمان اصلی تایید شده: دانشگاه علوم پزشکی مشهد (mashhad university of medical sciences) n mohamadian medical physics research center, faculty of medicine, mashhad university of medical sciences, mashhad, iranسازمان اصلی تایید شده: دانشگاه علوم پزشکی مشهد (mashhad university of medical sciences) d davenport comprehensive cancer centers of nevada, las vegas, nevada, usaسازمان اصلی تایید شده: دانشگاه علوم پزشکی مشهد (mashhad university of medical sciences)

background: ebt and ebt3 radiochromic films have been used in radiotherapy dosimetry for years. objective: the aim of the current study is to compare ebt and ebt3 radiochromic films in dosimetry of radiotherapy fields for treatment of parotid cancer. methods: calibrations of ebt and ebt3 films were performed with identical setups using a 6 mv photon beam of a siemens primus linac. skin dose was...

Maryam Papie, R Faghihi S Sina

Introduction: Contura is a balloon applicator that used to deliver intra cavity radiation for Partial Breast Irradiation (PBI) treatments. Contura with 4 peripheral lumens surrounding the central, for loading HDR sources from an after loader system can provide an asymmetric dose distribution and gives a more flexible shape of dose than earlier balloon applicators such as Mammo...

احمدی, ام لیلا, توکلی عنبران, حسین,

Introduction: The dosimetry of the brachytherapy sources is performed in the water source medium according to protocol TG-43U1. To achieve a resonable results on treatment, the use of the water material for all body tissues can be one of the faulty sources in delivering the correct dose to the tumor. Thus, we have focused on the dosimetry parameters in fat density 0.95 gr/cm3 and the muscle wit...

M. Amoui, M. Hosntalab, M.R. Teimoori Sichani, Sh. Akhlaghpoor,

Background: In this study, Quantitative 32P bremsstrahlung planar and SPECT imaging and consequent dose assessment were carried out as a comprehensive phantom study to define an appropriate method for accurate Dosimetry in clinical practice. Materials and Methods: CT, planar and SPECT bremsstrahlung images of Jaszczak phantom containing a known activity of 32P were acquired. In addition, Phanto...

Journal: :Journal of physics. Conference series 2009
H S Sakhalkar J Adamovics G Ibbott M Oldham

The potential of the PRESAGE™/Optical-CT system as a comprehensive 3D dosimetry tool has been demonstrated. The current study focused on detailed characterization of robustness (intra-dosimeter uniformity and temporal stability) and reproducibility (inter-dosimeter reproducibility) of PRESAGE™ inserts compatible with the RPC H&N phantom. In addition, the accuracy and precision of PRESAGE dose m...

Journal: :Medical physics 2012
Jose Perez-Calatayud Facundo Ballester Rupak K Das Larry A Dewerd Geoffrey S Ibbott Ali S Meigooni Zoubir Ouhib Mark J Rivard Ron S Sloboda Jeffrey F Williamson

PURPOSE Recommendations of the American Association of Physicists in Medicine (AAPM) and the European Society for Radiotherapy and Oncology (ESTRO) on dose calculations for high-energy (average energy higher than 50 keV) photon-emitting brachytherapy sources are presented, including the physical characteristics of specific (192)Ir, (137)Cs, and (60)Co source models. METHODS This report has be...

2012
Atsushi Komemushi Noboru Tanigawa Shuji Kariya Rie Yagi Miyuki Nakatani Satoshi Suzuki Akira Sano Koshi Ikeda Keita Utsunomiya Yoko Harima Satoshi Sawada

Purpose. To assess differences in dose distribution of a vertebral body injected with bone cement as calculated by radiation treatment planning system (RTPS) and actual dose distribution. Methods. We prepared two water-equivalent phantoms with cement, and the other two phantoms without cement. The bulk density of the bone cement was imported into RTPS to reduce error from high CT values. A dose...

2016
M.T. Bahreyni Toossi F. Khorshidi M. Ghorbani N. Mohamadian D. Davenport

BACKGROUND EBT and EBT3 radioChromic films have been used in radiotherapy dosimetry for years. OBJECTIVE The aim of the current study is to compare EBT and EBT3 radioChromic films in dosimetry of radiotherapy fields for treatment of parotid cancer. METHODS Calibrations of EBT and EBT3 films were performed with identical setups using a 6 MV photon beam of a Siemens Primus linac. Skin dose wa...

Journal: :Journal of radiological protection : official journal of the Society for Radiological Protection 2012
R Behrens

In the past the operational quantity H(p)(3) has been defined for calibration purposes in a slab phantom. Recently, an additional phantom in the form of a cylinder was suggested for eye lens dosimetry as a cylinder much better approximates the shape of a head than a slab. Therefore, this work investigates whether the quantity H(p)(3), when defined in the respective calibration phantom, adequate...