Journal: :Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology 2006
Tufve Nyholm Jörgen Olofsson Anders Ahnesjö Mikael Karlsson

BACKGROUND AND PURPOSE New treatment techniques in radiotherapy employ increasing dose calculation complexity in treatment planning. For an adequate check of the results coming from a modern treatment planning system, clinical tools with almost the same degree of generality and accuracy as the planning system itself are needed. To fulfil this need we propose a photon pencil kernel parameterizat...

Journal: :Journal of nuclear medicine : official publication, Society of Nuclear Medicine 2008
Joel S Karp Suleman Surti Margaret E Daube-Witherspoon Gerd Muehllehner

UNLABELLED Significant improvements have made it possible to add the technology of time-of-flight (TOF) to improve PET, particularly for oncology applications. The goals of this work were to investigate the benefits of TOF in experimental phantoms and to determine how these benefits translate into improved performance for patient imaging. METHODS In this study we used a fully 3-dimensional sc...

2010
Rolf-Dieter Bippus Andreas Goedicke Henrik Botterweck

Quantitative SPECT as well as simultaneous acquisition of multiple isotopes with SPECT in the clinical field, although clinically interesting, are still limited by reconstruction artifacts and computing power. As a considerable step in this direction, we have implemented an efficient reconstructor with variance reduced Monte-Carlo-simulation in the forward and/or backward projection of an OS-EM...

Journal: :AJR. American journal of roentgenology 2002
Jerry N King Anna M Champlin Charles A Kelsey David A Tripp

OBJECTIVE The purpose of this paper is to show the effectiveness of a new radiation protection method designed to decrease the amount of scatter radiation received by practitioners performing procedures under fluoroscopic guidance. MATERIALS AND METHODS A sterile, disposable, lead-free surgical drape containing radiation protection material composed primarily of bismuth was evaluated for effe...

Journal: :Journal of nuclear medicine : official publication, Society of Nuclear Medicine 2007
Jin Su Kim Jae Sung Lee Ki Chun Im Su Jin Kim Seog-Young Kim Dong Soo Lee Dae Hyuk Moon

UNLABELLED The microPET Focus 120 scanner is a third-generation animal PET scanner dedicated to rodent imaging. Here, we report the results of scanner performance testing. METHODS A (68)Ge point source was used to measure energy resolution, which was determined for each crystal and averaged. Spatial resolution was measured using a (22)Na point source with a nominal size of 0.25 mm at the syst...

Journal: :Journal of radiological protection : official journal of the Society for Radiological Protection 2014
David John Platten

Existing data used to calculate the barrier transmission of scattered radiation from computed tomography (CT) are based on primary beam CT energy spectra. This study uses the EGSnrc Monte Carlo system and Epp user code to determine the energy spectra of CT scatter from four different primary CT beams passing through an ICRP 110 male reference phantom. Each scatter spectrum was used as a broad-b...

Journal: :Nihon Hoshasen Gijutsu Gakkai zasshi 2006
Hideki Kato

The anti-scatter grid is generally used as a way of eliminating scattered radiation from X-ray photographs. This does not change even if the detector system changes from an analogue system to a digital system such as the flat-panel detector. We developed a new method that uses software to eliminate scatter components from digital X-ray images taken without the use of an anti-scatter grid. With ...

Journal: :iranian journal of radiation research 0
m. hajizadeh saffar department of medical physics, mashhad university of medical sciences, mashhad, iran s. nekoee department of medical physics, mashhad university of medical sciences, mashhad, iran m.h. bahrayni-toosi department of medical physics, mashhad university of medical sciences, mashhad, iran a. sedghi department of medical physics, mashhad university of medical sciences, mashhad, iran

abstractbackground: as fluoroscopy or different angiographies are usually evaluated using tl dosimeter. thismethod is a time-consuming procedure therefore, radiologists are usually worried and unawareof their exact radiation dose received during each fluoroscopy or angiography. in this study, anew trend for quick estimation of effective dose based on measuring air-absorbed dose of thescattered ...