نتایج جستجو برای: ptv margin
تعداد نتایج: 35795 فیلتر نتایج به سال:
Introduction: Radiation therapy involves a multistep procedure; therefore, the error in patient set up is an inherent part of the treatment. Main purpose of this study was to determine the clinical target volume (CTV) to planning target volume (PTV) in head and neck cancer patients. Material and Methods: A total of 15 patients who had daily p...
Concurrent chemoradiotherapy is considered the standard treatment for locally advanced cancer cervix (LACC). Radiotherapy commonly administered by a three-dimensional conformal radiotherapy (3DCRT) approach followed brachytherapy (BT). High dose rate (HDR) BT administered; however, several drawbacks exist including invasive technique, pain, requirement of anesthesia, and operative risks. We ass...
BACKGROUND AND PURPOSE To report single institution's IGRT and dosimetry analysis on the 37 Gy/5 fraction prostate SBRT clinical trial. MATERIALS/METHODS The IRB (Duke University Medical Center) approved clinical trial has treated 28 patients with stage T1-T2c prostate cancer with a regimen of 37 Gy in 5 fractions using IMRT and IGRT protocols since 2009. The clinical trial protocol requires ...
Teschovirus encephalomyelitis is a sporadic disease associated with Teschovirus A (PTV) serotype 1 and, less frequently, other serotypes. In recent years, the number of cases submitted to the Iowa State University Veterinary Diagnostic Laboratory with a history of posterior paresis has increased. Submission histories from various regions of the United States suggest a trend for clinical disease...
This study evaluated a method for prostate intensity-modulated radiation therapy (IMRT) based on edge-enhanced (EE) intensity in the presence of intrafraction organ deformation using the data of 37 patients treated with step-and-shoot IMRT. On the assumption that the patient setup error was already accounted for by image guidance, only organ deformation over the treatment course was considered....
Purpose/objective(s): To evaluate the dosimetric feasibility of a hypofractionated radiotherapy schedule for Stage III non-small cell lung cancers (NSCLC). Materials/Methods: The study sample included 14 cases. The mean tumor burden (primary and nodal areas) was 111 cm3, range 10-424 cm3. Intended plans consist of an initial dose of 40 Gy in 10 fractions, followed by a 7 Gy x 5 boost. The clini...
نمودار تعداد نتایج جستجو در هر سال