نتایج جستجو برای: reduced beam section

تعداد نتایج: 839247  

2009
Elena Angeli Chiara Manneschi Luca Repetto Giuseppe Firpo Corrado Boragno Ugo Valbusa

We propose a method for the separation of long DNA molecules, based on elastomeric nanochannels with tunable cross section. These nanoconfinement structures can be used to stretch DNA molecules and lower their conformational entropy. The sieving mechanism of entropic recoil, proposed by Cabodi et al. [1], will be implemented using an array of elastomeric nanocheannels. Structures of various dim...

2003
R. Lorenz S. Sabah H. J. Schreiber H. Waldmann

Cavity-type beam position monitors were developed to measure the beam alignment at the undulator section of DESY’s TESLA Test Facility (TTF). This paper describes some theoretical aspects and the experimental setup. The results of some in-beam measurements at the TTF are presented and pros and cons of the monitor concept are discussed.

2007
M. Marchetto A. Bylinskii R. E. Laxdal

The ISAC II superconducting linac is presently in the beam commissioning phase. The linac lattice consists of modules of four quarter wave cavities and one superconducting solenoid. At the moment five cryomodules (indicated as medium beta section) are installed. Beam steerers between cryomodules compensate for steering effects due to misalignments in the solenoids. Beam dynamics aspects of lina...

Journal: :Materials 2021

FRP (Fiber Reinforced Polymer) Bar reinforced coral concrete beam is a new type of structural member that has been used more and widely in marine engineering recent years. In order to study predict the flexural performance CFRP beams, rigidity, crack morphology failure mode were studied detail. The results show under condition similar reinforcement ratio, rigidity significantly lower than ordin...

In this article, M2 factor of a thin disk laser with unstable resonator in two regimes is calculated numerically. In the first case, thermal effects are ignored and the parameters of beam width, divergence angle, radius of wave front curvature and finally, M2 factor of laser beam are calculated by using generalized beam parameters. These calculations show that the beam quality of the laser is d...

Journal: :Physica Scripta 2022

Abstract The MUonE experiment has been proposed to measure the differential cross section of ? e elastic scattering, by colliding 160 GeV muons CERN M2 beam with atomic electrons thin target plates. From a very precise measurement shape one can achieve competitive determination leading hadronic contribution muon magnetic moment, independent from other existing ones. In preparation for Test Run ...

Journal: :journal of biotechnology and health sciences 0
maryam tofangchiha department of oral radiology, dental faculty, qazvin university of medical sciences, qazvin, ir iran faraz arianfar department of oral radiology, dental faculty, qazvin university of medical sciences, qazvin, ir iran mahin bakhshi department of oral medicine, dental faculty, shahid beheshti university of medical sciences, tehran, ir iran mansour khorasani department of oral and maxillofacial surgery, dental faculty, qazvin university of medical sciences, qazvin, ir iran; department of oral and maxillofacial surgery, dental faculty, qazvin university of medical sciences, qazvin, ir iran. tel: +98-2813353061

background cone beam computed tomography (ct) has recently become effective for oral and maxillofacial imaging. objectives the aim of this study was to assess the knowledge of dentists regarding cone beam computed tomography. materials and methods in this descriptive cross sectional study, a questionnaire regarding cone-beam computed tomography (cbct) was distributed amongst 100 dentists (gener...

2005
W. Narkbuakaew Chuchart Pintavirooj Withawat Withayachumnankul Manas Sangworasil S. Taertulakarn

Tomographic imaging is a technique for exploration of a cross-section of an inspected object without destruction. Normally, the input data, known as the projections, are gathered by repeatedly radiating coherent waveform through the object in a number of viewpoints, and receiving by an array of corresponding detector in the opposite position. In this research, as a replacement of radiographs, t...

2001
S. Bernal T. Godlove P. G. O’Shea M. Reiser

Results are presented of the first experiments with a 10 keV, 100 mA beam in the matching section for UMER. The section, about 1.5 m long, consists of one short solenoid, six printed-circuit (PC) quadrupoles, a bend PC dipole, a number of steering dipoles, and two sets of Helmholtz coils for balancing the Earth’s field. The 2 RMS beam radius as a function of axial distance in the straight part ...

Journal: :Journal of X-ray science and technology 2013
Fenglin Liu Ge Wang Wenxiang Cong Scott S Hsieh Norbert J Pelc

A bowtie is a filter used to shape an x-ray beam and equalize its flux reaching different detector channels. For development of spectral CT with energy discriminating photon-counting (EDPC) detectors, here we propose and evaluate a dynamic bowtie for performance optimization based on a patient model or a scout scan. With a mechanical rotation of a dynamic bowtie and an adaptive adjustment of an...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید