نتایج جستجو برای: selective membrane electrode

تعداد نتایج: 631334  

2012
Fikru Tafesse

Highly selective and sensitive phosphate sensors have been fabricated by constructing a solid membrane disk consisting of variable mixtures of aluminium powder (Al), aluminium phosphate (AlPO4) and powdered copper (Cu). Both binary and ternary electrode systems are produced. The ternary membranes exhibit greater selectivity over a wide range of concentrations. The ternary electrode with the com...

H. Aghaie M. Giahi M. Zawari

In this research, a PVC membrane electrode for Manganese (II) ions based on N-(2-Picolinamidoethyl)Picolinamide as neutral carrier was prepared. The electrode exhibits a Nemstian responseover Mn(II) concentration range of (1.0 x10-5 t01.0 X 10-1M) with a slope of 29.3±0.5 mV perdecade of concentration with a working pH range of 4.0-9.0. It has a fast response time (

H. Aghaie M. Aghaei M. Arvand3 M. Giahi1 Giahi

We found that dibenzo-18-crown-6 (DB18C6) can be used as an ionophore to make a tin (II)-ionselectivemembrane electrode. The electrode exhibits a near Nernstian response for Sn2+ ions over aconcentration range from 1.0× 10-6 – 1.0× 10-2 M with a slope of 27.5 ± 0.6 mV per concentration decadein an acidic solution (pH=1). The limit of detection was 8.0× 10-7 M. It has a response time of < 20s an...

2011
M. Soledad García Joaquín A. Ortuño María Cuartero Mustafa Salem Abuherba

The construction and characterization of a new ion-selective electrode for the determination of the antipsychotic ziprasidone in mixed solvents is presented. The electrode contains a plasticized polymeric membrane based on a ziprasidone-tetraphenylborate ion-exchanger. The influence of membrane composition on the electrode response towards ziprasidone in hydroalcoholic solutions was studied. Th...

Journal: :Analytical sciences : the international journal of the Japan Society for Analytical Chemistry 2003
Demet Kuruoğlu Esin Canel Shahabuddin Memon Mustafa Yilmaz Esma Kiliç

A hydrogen ion-selective poly(vinyl chloride) membrane electrode was constructed using 5,11,17,23-tetra-tert-butyl-25,26,27,28-tetracyanomethoxycalix[4]arene as a neutral carrier. The electrode showed an apparent Nernstian response in the 2-11.5 pH range with a slope of 54.0 +/- 0.2 mV/pH at 20 +/- degrees C. This electrode showed a rapid response of the emf to changes in the pH, high ion selec...

Journal: :Clinical chemistry 1990
M Rouilly B Rusterholz U E Spichiger W Simon

The concentration of free, ionized magnesium in undiluted blood serum can be determined potentiometrically with a new magnesium-selective carrier in polymeric membrane electrodes (by weight 66% plasticizer, approximately 33% polyvinyl chloride and approximately 1% ionophore). However, discrimination of calcium by the new ionophore-added membrane is not sufficient to keep calcium interference to...

H. Aghaie N. Farahani

Fe2+ ion-selective membrane sensor has been fabricated from polyvinyl chloride (PVC) matrixmembrane containing neutral carrier tetra phenyl porphyrin (TPP) ionophore. The addition ofsodium tetraphenylborate (NaTPB) and the plasticizer DBP has been found to substantiallyimprove the performance of the sensor. The best performance was obtained with the sensor havinga membrane of composition of TPP...

Journal: :Analytical sciences : the international journal of the Japan Society for Analytical Chemistry 2003
Alireza Asghari Mohammad K Amini Hassan R Mansour Masood Salavati-Niasari Maryam Rajabi

A nitrate-selective electrode based on a recently synthesized bis(2-hydroxyanil)acetylacetone lead(II) complex [(haacac)Pb] has been developed. Among different compositions studied, a membrane containing 30.7% poly(vinyl chloride) (PVC), 61.3% dibutyl phthalate (DBP) as a plasticizer, 3% methyltrioctylammonium chloride (MTOAC) as a cationic additive and 5% ionophore (all w/w) exhibited the best...

نمودار تعداد نتایج جستجو در هر سال