نتایج جستجو برای: sensor response

تعداد نتایج: 1150451  

Iryna Hunka Yaroslav Bazel Zholt Kormosh,

A simple, precise, rapid and low-cost potentiometric method for diclofenac determination in pharmaceuticals is proposed. A new diclofenac-sensitive electrode was constructed by incorporating the diclofenac ion pair complex with butyl rhodamine B into graphite matrix. The electrode exhibited a linear response over the concentration range of 1 × 10-4 – 5 × 10-2 mol L-1, a detection limit of 3.9×1...

2017
Nancy Elizabeth González-Sierra Luz del Carmen Gómez-Pavón Gerardo Francisco Pérez-Sánchez Arnulfo Luis-Ramos Plácido Zaca-Morán Jesús Manuel Muñoz-Pacheco Fernando Chávez-Ramírez

A comparative study on the sensing properties of a tapered optical fiber pristine and functionalized with the palladium nanoparticles to hydrogen and volatile organic compounds (VOCs), is presented. The sensor response and, response/recovery times were extracted from the measurements of the transient response of the device. The tapered optical fiber sensor was fabricated using a single-mode opt...

2014
Satoshi Tsuji Teruhiko Kohama

We proposed a tactile and proximity sensor (layered 3D touch screen) base on capacitance measurement. In the proposed sensor, the parallel-type capacitance sensor and plane-type capacitance sensor are layered. The sensor can detect the object and position before contact (proximity range), and can detect the indentation and precise position on contact. In addition, it can discriminate materials ...

2004
M. Afridi A. Hefner D. Berning C. Ellenwood A. Varma B. Jacob S. Semancik

The design and implementation of a monolithic micro electro mechanical systems (MEMS)-based gas sensor virtual component is described. The gas sensor virtual component encloses the sensor and its associated analog circuitry into a digital shell so that all interface connections to the virtual component are digital. The system architecture supports an array of gas sensor elements. System respons...

Highly textured undoped (pure) and Al doped ZnO nanocrystalline thin films prepared by ultrasonic atomization and pyrolysis method are reported in this paper. ZnCl2 water solution was converted into fine mist by ultrasonic atomizer (Gapusol 9001 RBI Meylan, France). The mist was pyrolyzed on the glass substrates in horizontal quartz reactor placed in furnace. The Structural and microstructural ...

Journal: :iranian journal of chemistry and chemical engineering (ijcce) 2001
mohammad kazem amini said shahrokhian sharam tangestaninejad iraj mohammadpoor baltork

a carbon-past electrode modified with iron(ii) phathalocyanine (fepc) was used as a sensitive potentiometric sensor for determination of 2-pyridinethiol (2pt). 2-mercaptoethanol (2me) and sulfide ion in aqueous solutions. the modified electrode acts as an electrocatalyst for oxidation of these compounds, and lowers the overpotential for oxidation reactions by more than 400 mv, compared to the u...

2016
Ian Yulianti

Optical sensors based on Fabry-Perot interferometer to detect cadmium ions is proposed. The sensor was fabricated by coating the tip of the optical fiber by chitosan. The two chitosan surfaces serve as mirrors which form a Fabry-Perot interferometer. The characterization results indicate that the sensor has a linear response with sensitivity of 0.0884 dBm/ppm with a correlation factor of 0.9665...

2010
Smitesh Bakrania Margaret S. Wooldridge

The current work presents the results of an experimental study of the effects of the location of gold additives on the performance of combustion-generated tin dioxide (SnO(2)) nanopowders in solid state gas sensors. The time response and sensor response to 500 ppm carbon monoxide is reported for a range of gold additive/SnO(2) film architectures including the use of colloidal, sputtered, and co...

A carbon Paste electrode modified with cobalt (II) phthalocyanine (CoPC) was used as a sensitive potentiometric sensor for determination of ascorbic acid in aqueous solutions. The potential response of the electrode is a linear function of ascorbic acid concentration over the range 5 10 to 10 M (?1- 1800 µg ML ) with a Nernstian slope of 56 mV at pH 7. The limit of detection was 0.2 µg ...

Journal: :Soft Comput. 2012
Olivier Strauss Agnès Rico

Reconstructing a signal from its observations via a sensor device is usually called “deconvolution”. Such reconstruction requires perfect knowledge of the impulse response of the sensor involved in the signal measurement. The lower this knowledge, the more biased the reconstruction. In this paper, we present a novel method for reconstructing a signal measured by a sensor whose impulse response ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید