نتایج جستجو برای: spacer

تعداد نتایج: 11027  

2017
Takashi Ogasawara Jun Sakata Yoichiro Aoshima Kazuki Tanaka Toshiaki Yano Norio Kasamatsu

Objective Among elderly patients with chronic obstructive pulmonary disease (COPD), there are some patients who cannot inhale tiotropium via Respimat® due to poor hand-lung coordination. This study aimed to examine whether or not tiotropium inhalation therapy using Respimat® with a spacer increased the forced expiratory volume in 1 s (FEV1) in patients with COPD. Methods A randomized, crossover...

Journal: :Telecommunication Systems 1994
F. Hübner Phuoc Tran-Gia

In this paper an analysis of a general spacer mechanism as used in ATM systems and being part of the usage parameter control functions is developed. The cell process which is subject to spacing can bearbitrarily chosen. The algorithm aims at the calculation of the spacer output process in term of the cell inter-departure time distribution, which g i v es insights to understand the traac stream ...

2017
Maria Koutroumani Georgios E. Papadopoulos Metaxia Vlassi Eleni Nikolakaki Thomas Giannakouros

Serine/arginine protein kinases (SRPKs) phosphorylate Arg/Ser dipeptide-containing proteins that play crucial roles in a broad spectrum of basic cellular processes. The existence of a large internal spacer sequence that separates the bipartite kinase catalytic core is a unique structural feature of SRPKs. Previous structural studies on a catalytically active fragment of SRPK1, which lacks the m...

Journal: :Molecular biology and evolution 1997
M L McKnight H B Shaffer

We report the presence, in the mitochondrial DNA (mtDNA) of all of the sexual species of the salamander family Ambystomatidae, of a shared 240-bp intergenic spacer between tRNAThr and tRNAPro. We place the intergenic spacer in context by presenting the sequence of 1,746 bp of mtDNA from Ambystoma tigrinum tigrinum, describe the nucleotide composition of the intergenic spacer in all of the speci...

Journal: :Orthopedics 2017
Bernd Preininger Viktor Janz Philipp von Roth Andrej Trampuz Carsten F Perka Tilman Pfitzner

Despite the lack of validation, synovial aspiration remains a common practice during 2-stage septic revision total knee arthroplasty (TKA). The goal of this study was to investigate the diagnostic validity of synovial polymethylmethacrylate (PMMA) spacer aspiration of temporary knee arthrodesis to detect persistent periprosthetic joint infection before TKA reimplantation. This retrospective coh...

Journal: :The Journal of biological chemistry 2002
Amy A Caudy Craig S Pikaard

Repeated within the intergenic spacers that separate adjacent ribosomal RNA (rRNA) genes in Xenopus laevis are several distinct sequence elements. These include transcription terminators, "region 0" repeats, "region 1" repeats, duplicated spacer promoters, and 42-bp enhancer elements that are embedded within 60 or 81-bp repeats. All have been reported to stimulate RNA polymerase I transcription...

Journal: :The European respiratory journal 1998
C J Kenyon L Thorsson L Borgström S P Newman

Electrostatic charge in plastic spacer devices has been shown in vitro to reduce delivery of asthma medications intended for inhalation, but the effect of static charge on in vivo drug deposition is unknown. A six-way randomized crossover study was conducted in 10 mild asthmatic patients. Two plastic spacers (Nebuhaler and Volumatic) and one metal spacer (Nebuchamber) were tested. The spacers w...

Journal: :Ophthalmology 2008
Bobby S Korn Don O Kikkawa Steven R Cohen Morris Hartstein Christine C Annunziata

PURPOSE To report a new technique in the repair of lower eyelid malposition using dermis fat as a posterior lamellar spacer graft. DESIGN Retrospective, consecutive, nonrandomized interventional case series. PARTICIPANTS Eleven patients who underwent surgical correction for symptomatic lower eyelid malposition using dermis fat as a spacer graft. METHODS Patients with symptomatic lower eye...

Journal: :Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology 2013
Michael Pinkawa Marc D Piroth Richard Holy Nuria Escobar-Corral Mariana Caffaro Victoria Djukic Jens Klotz Michael J Eble

BACKGROUND AND PURPOSE The aim was to evaluate the spacer dimensions and prostate position variability during the course of radiotherapy for prostate cancer. MATERIALS AND METHODS CT scans were performed in a group of 15 patients (G1) after the 10 ml injection of a hydrogel spacer (SpaceOAR™) and 30 patients without a spacer (G2) before the beginning of treatment (CT1) and in the last treatme...

Journal: :Thorax 1986
J F O'Reilly G Gould A H Kendrick G Laszlo

The bronchodilator response to cumulative doses of terbutaline administered by metered dose inhaler with and without a conical spacer device and by Acorn nebuliser has been compared in groups of patients with chronic severe and moderately severe asthma. After laboratory studies the patients undertook a randomised domiciliary crossover comparison of bronchodilator response to terbutaline given b...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید