نتایج جستجو برای: spiked calibration curve
تعداد نتایج: 185125 فیلتر نتایج به سال:
For optimal decision making under variable class distributions and misclassification costs a classifier needs to produce well-calibrated estimates of the posterior probability. Isotonic calibration is a powerful non-parametric method that is however prone to overfitting on smaller datasets; hence a parametric method based on the logistic curve is commonly used. While logistic calibration is des...
It is a common knowledge that detector fatigue causes a calibration curve to deviate from the preferred linear relationship at the higher concentration end. With the adaptation of an isotopically labeled analog of the analyte as the internal standard (IS), cross-contribution (CC) of the intensities monitored for the ions designating the analyte and the IS can also result in a non-linear relatio...
Rammed-earth (RE) is a construction material manufactured from the soil. The soil is compacted at its optimum water content, inside a formwork to build a monolithic wall. RE material is attracting renewed interest throughout the world thanks to its sustainable characteristics: low embodied energy, substantial thermal inertia, and natural regulator of moisture; on the other hand, the existing hi...
In this paper, we propose a blood pressure calculation and associated measurement method that by using a fiber Bragg grating (FBG) sensor. There are several points at which the pulse can be measured on the surface of the human body, and when a FBG sensor located at any of these points, the pulse wave signal can be measured. The measured waveform is similar to the acceleration pulse wave. The pu...
Abstract The electrochemical behavior of Vildagliptin (VILD) was studied using the cyclic voltammetric technique in an aqueous Britton–Robinson (BR) universal buffer solution various pH levels between 4.0 and 10 at a 5% calcium-montmorillonite clay modified with carbon paste electrode surface (5% Ca-MMT/CPE). results exhibited irreversible anodic peak about 1.238 V versus Ag/AgCl, KCl (3 mol L ...
ABSTRACT. The purpose of this study was to develop a method for the extraction and determination 2,4-dichlorophenoxyacetic acid (2,4-D) from soil, sediment, water, investigate its stability in water using high-performance liquid chromatography (HPLC). recoveries spiked compound soil samples found be range 80 100%. yield 2,4-D during acidification corresponding amine 93.84-99.98%. A calibration ...
Photomultipliers are commonly used in commercial PET scanner as devices which convert light produced in scintillator by gamma quanta from positron-electron annihilation into electrical signal. For proper analysis of obtained electrical signal, a photomultiplier gain curve must be known, since gain can be significantly different even between photomultipliers of the same model. In this article we...
Mass spectrometry is widely used in flavour research to quantify compounds by using isotopically labelled internal standards. However, equimolar amounts of different molecules do not give equal instrumental responses. Therefore, calibration of the mass spectrometer is needed prior to any sample quantification. If the mass of the internal standard differs from that of the analyte by more than 3 ...
Derivation of standard curves for the EMIT therapeutic drug monitoring system involves several mathematical algorithms, all of which can be rewritten in the form of a linear equation y = mx + b. We examined the stability of the standard curve in terms of slope and y-intercept for three drug assays (procainamide, gentamicin, and carbamazepine) by generating calibration curves intermittently for ...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید