نتایج جستجو برای: sutureless vitrectomy

تعداد نتایج: 4989  

2014
Taiichi Hikichi Hirokuni Kitamei Shoko Kosaka Shoko Shioya Kimitaka Takami

BACKGROUND The purpose of this study was to determine the incidence of vitreous incarceration in sclerotomy after cannula removal during 23-gauge vitrectomy. METHODS Thirty-seven eyes underwent 23-gauge sutureless vitrectomy. Oblique sclerotomies were made parallel to the limbus and tangentially to the sclera. Once past the trocar sleeve, the angle was changed to 90 degrees perpendicular to t...

2014
Yong-Kyu Kim Yong Woo Kim Se Joon Woo Kyu Hyung Park

PURPOSE The 2.2-mm microincision cataract surgery and small-gauge vitrectomy system is known to result in less surgically-induced astigmatism (SIA) in comparison to conventional surgical methods. We compared the amounts of SIA after combined phacoemulsification and 23-gauge transconjunctival sutureless vitrectomy (23G-TSV) using the 2.2-mm microincision and 2.75-mm standard incision methods. ...

2016
Spyridon E. Chalkiadakis Efstratios A. Parikakis Simon R.J. Taylor

BACKGROUND The surgical case of a dropped intraocular lens inside the vitreous cavity constitutes a real challenge for the operating surgeon. Herein, we describe a case series where an alternative optical rehabilitation technique for late intraocular lens-bag complex dislocation has been used. METHODS A modern vitrectomy device was used to remove the capsule with the dropped intraocular lens ...

2016
Nisar Ahmed Siyal Lakhani Das Hargun Shahid Wahab

OBJECTIVE To study the outcomes of passive removal of silicone oil by 23 Gauge Transconjunctival Sutureless Vitrectomy System. METHODS This prospective, consecutive case series study was conducted at Ophthalmology Department Unit I, Dow University of Health Sciences, Civil Hospital Karachi from January 2011 to December 2014. Only psuedophakic eyes with silicone oil temponade were selected. Ma...

2016
Zhong Lin Zhi Sheng Ke Qian Zheng Zhen Quan Zhao Zong Ming Song

Purpose. To report a new approach for removal of silicone oil. Methods. All surgeries were performed using 23-gauge vitrectomy system with two transconjunctival sutureless cannulas. At the beginning, most of the silicone oil was removed by traditional microinvasive vitrectomy system through inferior-temporal cannula. Then, the blood transfusion tube is removed from the inferior-temporal cannula...

2012
Shozo Sonoda Katsuro Tachibana Toshifumi Yamashita Makoto Shirasawa Hiroto Terasaki Eisuke Uchino Ryo Suzuki Kazuo Maruyama Taiji Sakamoto

This paper aims to evaluate the efficacy of intravitreal ultrasound (US) irradiation for green fluorescent protein (GFP) plasmid transfer into the rabbit retina using a miniature US transducer. Intravitreal US irradiation was performed by a slight modification of the transconjunctival sutureless vitrectomy system utilizing a small probe. After vitrectomy, the US probe was inserted through a scl...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید