نتایج جستجو برای: thermal lens microscopy
تعداد نتایج: 450243 فیلتر نتایج به سال:
This is a preliminary study for microscopic lens thermography observations on a film-like and non-blackbody material. With this aim, a number of features present on the surface of a cardboard for storage boxes (grammage 300 g/m2) are observed using a Flir SC 3000 thermal imager microscopic lens with 26 mm fixed focal distance. Comments on quality of observation and on probability of false indic...
Laser illumination used in both conventional widefield epi-fluorescence as well as in total internal reflection fluorescence (TIRF) microscopy is subject to nonuniformities in intensity that obscure true image details. These intensity variations are interference fringes arising from coherent light scattering and diffraction at every surface in the laser light's optical path, including the lense...
Thin section electron microscopy reveals two different types of membrane interactions between the fiber cells of bovine lens. Monoclonal antibodies against lens membrane protein MP70 (Kistler et al., 1985, J. Cell Biol., 101:28-35) bound exclusively to the 16-17-nm intercellular junctions. MP70 localization was most dramatic in the lens outer cortex and strongly reduced deeper in the lens. In c...
PURPOSE The expression of the Sigma 1 receptor and the ability of receptor antagonists to inhibit growth and induce pigment formation were investigated in human lens epithelial cells. METHODS Capsular bags were formed for experimental purposes by performing sham cataract operations on donor lenses. The resultant bags were cultured in Eagle's minimum essential medium (EMEM) alone or supplement...
Biotrue multipurpose solution (MPS) is a bioinspired disinfecting and conditioning solution that includes hyaluronic acid (HA) as a natural wetting agent. Previous studies demonstrated that HA sorbed from Biotrue MPS on both conventional and silicone hydrogel (SiHy) contact lens materials; an in vitro simulated-wear test validated the presence of HA on the lens surfaces for as long as 20 hours....
BACKGROUND Phacolytic glaucoma is induced by lens protein or macrophages that have leaked through a macroscopically intact anterior lens capsule. Here, we report a case of phacolytic glaucoma with anterior lens capsule disruptions visualized by scanning electron microscopy (SEM). CASE PRESENTATION A 71-year-old man was referred to our institute for increased intraocular pressure (IOP) in the ...
Microscopic images are characterized by a number of microscope-specific parameters--numerical aperture (NA), magnification (M), and resolution (R)--and by parameters that also depend on the specimen--for example, contrast, signal-to-noise ratio, dynamic range, and integration time. In this article, issues associated with the microscope-specific parameters NA, M, and R are discussed with respect...
A comparative study of thermal lensing effect in diode laser pumped Ng- and Np-cut Nd:KGd(WO4)2 (KGW) laser crystals was performed for laser emission polarized along the principle refractive axis, Nm. The thermal lens in the Ng-cut Nd: KGW was found to be weakly astigmatic with a positive refractive power for both the Nm- and Np-directions. For Np -cut Nd:KGW, strong astigmatism was observed an...
We use a femtosecond pump-probe Z-scan technique to measure the thermal lens (TL) signal in a homologous series of primary alcohols. The trend in these experimentally measured TL signals deviates in a counterintuitive manner from the ones calculated using theoretical models that are only based on the macroscopic parameters. Introspection shows that the present TL theories are based on heat cond...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید