نتایج جستجو برای: thermoluminescence dosimeters tld

تعداد نتایج: 3413  

2001
A. N. YAZICI Z. ÖZTÜRK M. BEDİR

In this study, a new simple model based on the classical treatment of lattice vibrations and the Franck-Condon principle is developed to describe the shape of thermoluminescence (TL) emission bands of crystalline solids. According to developed model, shape of the emission band has a Gaussian form and depends on just two physical parameters: peak energy E0 and broadening of emission spectra U. I...

Journal: :AJNR. American journal of neuroradiology 2016
P Yang A Ahmed S Schafer D Niemann B Aagaard-Kienitz K Royalty C Strother

BACKGROUND AND PURPOSE Volume-of-interest C-arm CT is a novel technique for imaging of intracranial high-contrast objects. We performed this study to evaluate the potential diagnostic value and radiation dose reduction of this technique for imaging of intracranial stents and flow diverters. MATERIALS AND METHODS Twenty-seven patients were imaged with a VOI C-arm CT scan following treatment wi...

Journal: :Journal of physics 2022

Abstract The results reported herein were motivated by the potential application of combined optically stimulated (OSL) and thermoluminescence (TL) measurements for separation between beta neutron dose components in mixed neutron-beta radiation fields. advantages OSL/TL are two-fold: (i) OSL TL readout can be carried out on same sample (ii) greater efficiency to high ionization density (HID) du...

Journal: :Radiation protection dosimetry 2006
Christopher Soares Chris Drupieski Brian Wingert Garey Pritchett Vasilis Pagonis Michelle O'Brien Alan Sliski Pawel Bilski Pawel Olko

Absorbed dose rate measurements of a 50 kV(p) handheld X-ray probe source in a water phantom are described. The X-ray generator is capable of currents of up to 40 microA, and is designed for cranial brachytherapy and intraoperative applications with applicators. The measurements were performed in a computer-controlled water phantom in which both the source and the detectors are mounted. Two dif...

ژورنال: سنجش و ایمنی پرتو 2017

Thermal quenching is a known and important effect which should be taken into account in studying thermoluminescence (TL) phenomenon. This effect causes the probability of non-radiative recombinations to be increased with raising temperature in TL process. This article deals with changes of the TL glow curve of LiF:Mg, Ti (TLD-100) with heating rate. It was observed that the main dosimetry peak ...

2013
Lukkana Apipunyasopon Somyot Srisatit Nakorn Phaisangittisakul

The percentage depth dose in the build-up region and the surface dose for the 6-MV photon beam from a Varian Clinac 23EX medical linear accelerator was investigated for square field sizes of 5 × 5, 10 × 10, 15 × 15 and 20 × 20 cm(2)using the EGS4nrc Monte Carlo (MC) simulation package. The depth dose was found to change rapidly in the build-up region, and the percentage surface dose increased p...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید