نتایج جستجو برای: tips method

تعداد نتایج: 1642791  

2017
Upendra Sharan Gupta Abhishek Chaturvedi Nishant Patel Nikhil Kumar Pandey

Carbon nanotubes have been of great interest because of their simplicity and ease of synthesis. The novel properties of nanostructured carbon nanotubes such as high surface area, good stiffness, and resilience have been explored in many engineering applications. Research on carbon nanotubes have shown the application in the field of energy storage, hydrogen storage, electrochemical supercapacit...

Journal: :Journal of clinical gastroenterology 2007
Luis Colombato

Transjugular intrahepatic portosystemic shunt (TIPS) is an interventional radiology technique that has shown a 90% success rate to decompress the portal circulation. As a non-surgical intervention, without requirement for anesthesia and very low procedure-related mortality, TIPS is applicable to severe cirrhotic patients, who are otherwise untreatable, for example, nonsurgical candidates. TIPS ...

Journal: :Journal of clinical pathology 2004
F Biagi O Luinetti J Campanella C Klersy C Zambelli V Villanacci A Lanzini G R Corazza

BACKGROUND The counting of intraepithelial lymphocytes (IELs) in the villous tips of architecturally normal small bowel biopsy specimens was proposed as a method to measure mucosal infiltration in gluten sensitive patients. AIMS To apply this straightforward method in duodenal biopsy specimens from patients affected by potential coeliac disease (PCD) to verify whether it can discriminate thes...

Journal: :Analytical sciences : the international journal of the Japan Society for Analytical Chemistry 2014
Tomoaki Nishino

This paper reviews the development of molecular tips for scanning tunneling microscopy (STM). Molecular tips offer many advantages: first is their ability to perform chemically selective imaging because of chemical interactions between the sample and the molecular tip, thus improving a major drawback of conventional STM. Rational design of the molecular tip allows sophisticated chemical recogni...

Journal: :The Analyst 2013
Taekyeong Kim Ki-Seok Jeon Kwang Heo Hyung Min Kim Juhun Park Yung Doug Suh Seunghun Hong

We presented a scalable fabrication method for the preparation of multilayered nano-prism vertex (NV)-tips whose dimensions can be controlled for tip-enhanced Raman spectroscopy (TERS). The NV-tip had sharp vertices (diameter ~20 nm) originated from the chemical lift-off process after the angle-grinding process, enabling high resolution imaging. TERS measurements were performed on brilliant cre...

Journal: :The Review of scientific instruments 2007
M Greiner P Kruse

Atomically sharp tungsten tips made from single crystal tungsten wire are superior to those made from cold-drawn polycrystalline wire but are rarely used due to their high price. We have devised a method of obtaining highly crystalline tungsten wire by recrystallizing cold-drawn wire. The effect of various heat treatments on the wire microstructure was observed using scanning electron microscop...

2016
Eunyoung Kim Sung Won Lee Woo Hyeon Kim Si Hyun Bae Nam Ik Han Jung Suk Oh Ho Jong Chun Hae Giu Lee

A 43-year-old man with liver cirrhosis received transjugular intrahepatic portosystemic shunt (TIPS) for the treatment of recurrent variceal bleeding and F3 esophageal varices. During routine follow up liver ultrasound examination, six months after the implantation, TIPS occlusion was suspected and TIPS revision was performed. During the revision, moderate to severe stenosis at the hepatic veno...

Journal: :Journal of Archaeological Method and Theory 2022

Work on large samples of southern African archaeological lithics, probably used to tip hunting weapons amongst other things, and ethno-historical bone iron weapon tips known use exposed limitations in the cross-sectional area (TCSA) method’s robustness for hypothesising about variation ancient weapon-delivery systems. Here, we list some discuss a few recently published improvements ranges data ...

2006
Daniel J. Burns Kamal Youcef-Toumi

A method is presented to indirectly measure and shorten carbon nantoubes grown from the tips of atomic force microscope (AFM) probes. The measurement component exploits the nanotubes ability to elastically buckle and requires only those signals and actuators available on a standard AFM. The shortening operation is facilitated by electric arcing using a conducting niobium substrate. The shorteni...

ذوالنوریان, حیدر, عظیمی, محمدرضا, مرادی, سهیلا, پورداد, سعید,

Synthetic seeds can use as tool for applied biotechnology methods for improve the quality and increase the production of sunflower. Shoot tips excised from in vitro proliferated shoots were encapsulated in calcium alginate beads. The best gel complexation was achieved using 3% sodium alginate and 100 mM CaCl2.2H2O. Maximum percentage response for conversion of encapsulated shoot tips into plant...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید