نتایج جستجو برای: transformer

تعداد نتایج: 11481  

2013
AKSHAY A. PANDYA

Sweep frequency response analysis is a major advance in transformer condition analysis. Frequency response is performed by applying a low voltage signal of varying frequencies to the transformer windings and measuring both the input and output signals. The ratio of these two signals gives the required response. This ratio is called the transfer function of the transformer from which both the ma...

2014
Guang Ya LIU Xing ZHANG Lu KANG

Partial discharge inside a transformer is mainly responsible for the insulation aging and damage of the transformer. However, partial discharge is usually accompanied by external signals like sound, light and electrical signals and detectable physical phenomena such as characteristical gas and dielectric loss. Therefore, it is of great significance to monitor online the external signals and phe...

Journal: :IEICE Transactions 2008
So Bong Shin Sang-Gug Lee

A differential LC-VCO that adopts a transformer with asymmetric turns-ratio has been proposed. The asymmetric turns-ratio of the transformer leads to the suppression of the AM to FM conversion which is caused by the 1/f noise of the current source transistor. The analysis of the proposed scheme and the improvement in phase noise compare to conventional CMOS LC-VCOs are described. The transforme...

2007
W. H. Tang S. He Q. H. Wu

This paper presents a new approach to identify distributed parameters of a lumped-element model for a power transformer. A simplified circuit of a lumped-element model is developed to calculate frequency responses of transformer windings in a wide range of frequency domain. In order to seek optimal parameters of the simplified circuit of the transformer, an intelligent learning technique, based...

2012
H. Canacsinh J. Fernando A. da Silva Sónia Ferreira Pinto Luis M. Redondo João Santana

The purpose of this paper is to present and discuss a general HV topology of the solid-state Marx modulator, for unipolar or bipolar generation connected with a step-up transformer to increase the output voltage applied to a resistive load. Due to the use of an output transformer, discussion about the reset of the transformer is made to guarantee zero average voltage applied to the primary. It ...

2014
Xiaohui Wang Kehe Wu Yang Xu

DGA (Dissolved Gas Analysis) is the traditional transformer fault diagnosis method, but it mainly depends on the experience of operators. In order to solve the limitations of traditional method, this paper introduces intelligent method for fault diagnosis of transformer. The intelligent method made fusion of various data, including SCADA data, oil dissolved gas sensor data, related electrical t...

2009
G. Bajracharya T. Koltunowicz R. R. Negenborn Z. Papp D. Djairam B. De Schutter J. J. Smit

In this paper, a model predictive framework is used to optimize the operation and maintenance actions of power system equipment based on the predicted health sate of this equipment. In particular, this framework is used to predict the health state of transformers based on their usage. The health state of a transformer is hereby given by the hot-spot temperature of the paper insulation of the tr...

2013
Ashfaq Ahmad Waseem Nazar

The objective of this research is to compute the mechanical stresses in power transformer resulting from the currents more than rated value during its operation. Due to this high fault current, mechanical stresses are produced indifferent directions which may cause the damage of winding insulation. Various techniques have been adopted to analyze the stresses on transformer windings. For the acc...

2001
Seong-Jeub Jeon Gyu-Hyeong Cho

A new primary-side-assisted zero-voltage and zerocurrent switching full bridge dc–dc converter with transformer isolation is proposed. The proposed dc–dc converter uses only one auxiliary transformer and two diodes to obtain ZCS for the leading leg. It has a simple and robust structure, and load current control capability even in short circuit conditions. Possibility of magnetic saturation due ...

2012
Rushi R. Desai Amit N. Patel Vinod R. Gupta

The internal faults of transformer can be identified by various techniques. The proposed technique is by the analysis of no-load current and harmonic contents present in it. The no-load current of transformer is non-sinusoidal for sinusoidal input voltage. And hence it contains harmonics in healthy condition of transformer. But if transformer has any internal fault then the no-load current magn...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید