نتایج جستجو برای: union fractures

تعداد نتایج: 116375  

Journal: :JPMA. The Journal of the Pakistan Medical Association 2001
R Hussain M Umer M Umar

OBJECTIVE To assess the efficacy of flexible intramedullary Ender nails for the treatment of tibial diaphyseal. MATERIALS AND METHODS This is a retrospective review of patients treated with the Ender Nail for both open and closed tibial shaft fractures. Between January 1989 and December 1994, 43 fractures were treated with these nails. The configuration of each fracture was determined using t...

2014
R. Pascarella C. Bettuzzi G. Bosco D. Leonetti S. Dessì P. Forte L. Amendola

Indications and techniques of locked plate fixation for the treatment of challenging fractures continue to evolve. As design variant of classic locked plates, the polyaxial locked plate has the ability to alter the screw angle and thereby, enhance fracture fixation. The aim of this observational study was to evaluate clinical and radiographic results in 89 patients with 90 fractures of the dist...

Journal: :Nepal Medical College journal : NMCJ 2012
P K Chalise A K Mishra S B Shah V Adhikari R P Singh

Pertrochantric femoral fractures are one of the most common fracture in old patients with variety of complications. However fixing Pertrochantric femoral fractures properly is clinically challenging. We report the outcome of pertrochantric femoral fractures treated with Proximal Femoral Locking Compression Plate (PFLCP) using Minimal Invasive Percutaneous Plate Osteosynthesis (MIPPO) techniques...

Journal: :Journal of orthopaedic surgery 2012
Sachit Malhan Simon Thomas Shekhar Srivastav Sshekhar Agarwal Vivek Mittal Biren Nadkarni Divesh Gulati

PURPOSE To assess outcomes of minimally invasive plate osteosynthesis (MIPO) using a locking compression plate (LCP) for 42 humeral shaft fractures. METHODS. 28 men and 14 women aged 18 to 68 (mean, 34; median, 29) years underwent closed reduction and MIPO using a LCP for type 12-A (n=26) and type 12-B (n=16) humeral shaft fractures. Eight of the patients were aged ≥ 50 years. Patients were fol...

Journal: :Orthopedics 2015
Yu Fan Yue-Wang Li Hong-Bo Zhang Jian-Fei Liu Xiang-Min Han Xiao Chang Xi-Sheng Weng Jin Lin Bao-Zhong Zhang

Surgical fixation of humeral shaft fractures generally involves plating or nailing. It is unclear whether one method is more effective than the other. The aim of this study was to compare the results of the intramedullary nail and locking compression plate for the treatment of humeral shaft fractures. A total of 60 patients with humeral shaft fractures were randomized to undergo surgery with an...

Journal: :Genetics and molecular research : GMR 2014
Q Li B F Zeng C F Luo S Song C Q Zhang W Q Kong

The aim of this study was to compare the effects and indications of minimally invasive plate osteosynthesis (MIPO) and limited open reduction (LOR) for managing distal tibial shaft fractures. A total of 79 cases of distal tibial shaft fractures were treated surgically in our trauma center. The 79 fracture cases were classified into type A, B, and C (C1) according to the Arbeitsgemeinschaft für ...

Journal: :Journal of orthopaedic surgery 2009
Amit B Putti Rajendra B Uppin Babu B Putti

PURPOSE. To compare functional outcomes, union and complication rates in patients treated with locked intramedullary nailing or dynamic compression plating for humeral shaft fractures. METHODS. 32 men and 2 women with humeral shaft fractures were randomised to undergo locked antegrade intramedullary nailing (IMN, n=16) or dynamic compression plating (DCP, n=18). Patients with pathological fract...

Journal: :Journal of orthopaedic science : official journal of the Japanese Orthopaedic Association 2004
George Petsatodes Dimitrios Karataglis Pericles Papadopoulos John Christoforides John Gigis John Pournaras

The results of 39 humeral shaft fractures (37 patients) treated with antegrade locked nailing using a Russell-Taylor nail were reviewed. There were 30 acute fractures, 6 fractures malaligned in a hanging cast or brace, and 3 pathological fractures. Patient age ranged from 26 to 80 years (average, 59.7 years) and average follow-up was 25.7 months (range, 6-48 months). Fracture union was achieved...

Journal: :Journal of orthopaedic surgery 2012
Ismail Oytun Salih Marangoz

PURPOSE To evaluate outcome of intramedullary nailing supplemented with Poller screws for proximal tibial fractures using small diameter nails. METHODS 50 men and 20 women (75 fractures) aged 18 to 65 (mean, 33) years underwent intramedullary nailing supplemented with Poller screws for acutely displaced fractures (n=60) or for delayed union (n=10) or mal-union (n=5) of the proximal metadiaphy...

2014
Nai-Feng Tian Xu-Qi Hu Li-Jun Wu Xin-Lei Wu Yao-Sen Wu Xiao-Lei Zhang Xiang-Yang Wang Yong-Long Chi Fang-Min Mao

BACKGROUND Anterior odontoid screw fixation (AOSF) has been one of the most popular treatments for odontoid fractures. However, the true efficacy of AOSF remains unclear. In this study, we aimed to provide the pooled rates of non-union, reoperation, infection, and approach related complications after AOSF for odontoid fractures. METHODS We searched studies that discussed complications after A...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید