نتایج جستجو برای: ur metal artifacts

تعداد نتایج: 232282  

Journal: :Medical physics 2012
D Seghers T Berkus M Oelhafen P Munro J Star-Lack

PURPOSE To compare four metal-artifact-reduction (MAR) algorithms in their ability to correct the typical streaking artifacts that appear in cone- beam computed tomography (CBCT) images. METHODS The goal was to compare the strengths and weaknesses of four MAR algorithms, Basic; Wei; Mazin and Meyer, using typical clinical situations where metal is present. Three clinical situations were evalu...

Journal: :Medical physics 2013
Jun Wang Shijie Wang Yang Chen Jiasong Wu Jean-Louis Coatrieux Limin Luo

PURPOSE In computed tomography, metallic objects in the scanning field create the so-called metal artifacts in the reconstructed images. Interpolation-based methods for metal artifact reduction (MAR) replace the metal-corrupted projection data with surrogate data obtained from interpolation using the surrounding uncorrupted sinogram information. Prior-based MAR methods further improve interpola...

Journal: :Environmental toxicology and chemistry 2003
Lennart Weltje Wim Den Hollander Hubert Th Wolterbeek

Filtration of a solution may lower metal concentrations through adsorption of metal species to the filter. Processes such as filter-sterilizing nutrient solution and filtration of field water are sensitive to these sorption artifacts, yet basic data on the affinity of different filters for metals are lacking. This article describes the adsorption of five metals to eight types of 0.2-microm memb...

2017
Mehran Yazdi Maryam Mohammadi

In X-ray computed tomography (CT), the presence of metal objects in a patient's body produces streak artifacts in the reconstructed images. During the past decades, many different methods were proposed for the reduction or elimination of the streaking artifacts. When scanning a patient, the projection data affected by metal objects (missing projections) appear as regions with high intensities i...

2014
Sung Han Kim Changwon Yoo Minsoo Choo Jae-Seung Paick Seung-June Oh

OBJECTIVE Patients can experience urinary retention (UR) after Holmium laser enucleation of the prostate (HoLEP) that requires bladder distension during the procedure. The aim of this retrospective study is to identify factors affecting the UR after HoLEP. MATERIALS AND METHODS 336 patients, which underwent HoLEP for a symptomatic benign prostatic hyperplasia between July 2008 and March 2012,...

2016
Hyoung Suk Park Hao Gao Jin Keun Seo H. S. PARK H. GAO S. M. LEE

High-attenuation object-induced streaking and shadow artifacts in computerized tomography (CT) are somewhat connected to the misfit of the X-ray projection data to the range space of the Radon transform. This misfit is mainly due to the beam hardening factor of the projection data which is unavoidable for polychromatic sources. The major difficulty in dealing with the beam hardening-induced str...

Journal: :Medicina oral, patologia oral y cirugia bucal 2009
Andre L F Costa Simone Appenzeller Clarissa-Lin Yasuda Fabrício R Pereira Verônica A Zanardi Fernando Cendes

OBJECTIVE Artifacts caused by metallic objects, such as dental crowns, dental implants and metallic orthodontic appliances, are a common problem in head and neck MRI. The aim of this retrospective study was to identify the main metal dental objects that produce artifacts on brain MRIs. STUDY DESIGN Imaged metallic artifacts and their sources were identified. Artifact image plane was rated on ...

1996
Bernhard Rumpe

Dieser Artikel fa t die wesentlichen Ergebnisse sowie einige H ohepunkte der Dissertation zusammen Es wird eine methodische Grundlage f ur die Spezi kation von Struktur und Verhalten verteilter objektorientierter Systeme skiz ziert Es werden Beschreibungstechniken f ur Klassen und Zustandsdiagramme de niert und ein Verfeinerungskalk ul f ur diese angegeben Insbesondere wird in diesem Artikel de...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید