This paper presents the transient stability analysis of a pressurised water-type nuclear power plant following faults and disturbances affecting electricity grid to which it is connected. The modelled consists various integrated subsystems, such as core neutronics thermal-hydraulics, piping plenum, pressuriser, steam generator, turbine, governor, dynamics shaft, in addition turbine-speed contro...