نتایج جستجو برای: ventricular septal occluder device endocarditis

تعداد نتایج: 845581  

Journal: :The Journal of Thoracic and Cardiovascular Surgery 2012

Journal: :Circulation. Cardiovascular interventions 2012
Derek A Williams Yoshio Ootaki Michael D Quartermain

A 4-year-old asymptomatic girl presented for elective transcatheter closure of her ostium secundum atrial septal defect (ASD). Her examination revealed a fixed split second heart sound with a 2/6 systolic ejection murmur at the left upper sternal border and a right ventricular lift. Transthoracic echocardiogram demonstrated a 15-mm secundum ASD with a mildly dilated right ventricle. The left co...

Journal: :Singapore medical journal 2012
P K Goel A Kapoor

This case report describes a modification in the technique of atrial septal device closure in a patient with atrial septal defect (ASD) with associated atrial septum aneurysm and significant left-to-right shunt through multiple perforations. Graded balloon dilatation of the aneurysm was performed in this patient, as a preamble to successful deployment of a single large Amplatzer atrial septal o...

Journal: :Interactive cardiovascular and thoracic surgery 2005
Jan Vojácek Martin Mates Jana Popelová Petr Pavel

Transcatheter closure of secundum atrial septal defect has become an alternative to surgery. We present a patient with hemodynamic collapse secondary to cardiac perforation occurring 36 h after the placement of an Amplatzer Septal Occluder and discuss complications of this kind of device.

Journal: :Pediatrics and neonatology 2011
Yun-Ching Fu

Traditional treatment of muscular ventricular septal defect (VSD) is surgical closure, but it carries considerable morbidity and mortality. The Amplatzer muscular VSD occluder (AGA Medical Corporation, Plymouth, MN, USA) was approved by the United States Food and Drug Administration in September 2007 and by the Taiwan Department of Health in September 2009. It is a self-expandable double-disc d...

2013
Prashant N Mohite Sachin A Kuthe Shrirang D Ranade Pravin P Kulkarni Anton Sabashnikov Aron F Popov

As the use of percutaneous intervention is increasing for the closure of the atrial septal defect, the procedure related complications are also on rise, migration of the device being most common. The migrated devices with failed percutaneous retrieval must be removed surgically under cardiopulmonary bypass. During establishment of cardiopulmonary bypass, the handling of heart may cause further ...

2017
Hyo-Hyun Kim Gi-Jong Yi Suk-Won Song

Percutaneous closure of atrial septal defect (ASD) has become an increasingly common procedure. Serious complications of the procedure, such as cardiac migration, are rare, and usually occur <72 hours after device placement. In this report, we present the case of a patient who underwent successful surgical treatment for the migration of an ASD occluder device to the thoracic aorta 12 months aft...

Journal: :World Journal of Cardiovascular Surgery 2022

Surgical intervention for post-infarct ventricular septal defect (VSD) is a challenging procedure due to patients’ complex preoperative conditions. While percutaneous VSD closure can be considered as an alternative surgical repair, complete of the remains difficult and associated with various procedural complications. We report rare case patient postoperative residual shunts who experienced rec...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید