Described are the design procedure and measured performance of a PA targeted for the W-CDMA downlink band exhibiting over 84% PAE at 2.14 GHz. The PA is designed with an uncharacterised GaN HEMT. A measurement-based design approach is used to optimise the source and load impedance at the fundamental frequency with classF harmonic terminations enforced. S-parameters extracted from a full-wave EM...

2012
Ahmed Hossam-Eldin Ahmed Elserougi Ahmed Massoud Shehab Ahmed

The Inter feeder Power Flow Regulator (IFPFR) proposed in this paper consists of several voltage source inverters with common dc bus; each inverter is connected in series with one of different independent distribution feeders in the power system. This paper is concerned with how to transfer power between the feeders for load sharing purpose. The power controller of each inverter injects the pow...

2015
Lianqing Zheng Chen Zhuang Jian Zhang Xiong Du

Due to the line impedance impact on islanded low-voltage microgrids, traditional droop control cannot guarantee the proper power sharing between distributed generation (DG) units. In the meanwhile, droop control would cause voltage and frequency deviation, which will influence the power quality of customers. This paper proposed an enhanced droop control scheme with autonomous frequency restorat...

Journal: :IEICE Transactions 2011
Kamya Yekeh Yazdandoost Kamran Sayrafian-Pour Kiyoshi Hamaguchi

Wireless body area network for sensing and monitoring of vital signs is the one of most rapidly growing wireless communication system and Ultra Wide-Band (UWB) is a favorable technology for wearable medical sensors. The wireless body area networks promise to revolutionize health monitoring. However, designers of such systems face a number of challenging tasks. Efficient transceiver design requi...

Journal: :Protection and Control of Modern Power Systems 2023

Abstract The high proportion of nonlinear and unbalanced loads results in power quality issues islanded microgrids. This paper presents a novel control strategy for harmonic allocation among distributed generators (DGs) Different from the existing sharing strategies that allocate according to rated capacities DGs, proposed intends shape lowest output impedances DGs optimize microgrid. To achiev...

Journal: :Iet Generation Transmission & Distribution 2021

Classic droop control ensures the synchronization of distributed generation (DG) units inside a microgrid without requiring any deployment communication links, however it causes unwanted frequency fluctuations and degrades system dynamics. Angle V ? I have been developed as two major global positioning (GPS)-based methods, both which realize fixed-frequency operation through synchronizing DG wi...

2001
Reza Azadegan Kamal Sarabandi

With the virtual enforcement of the required boundary condition (BC) at the end of a slot antenna, the area occupied by the resonant antenna can be reduced. To achieve the required virtual BC, the two short circuits at the end of the resonant slot are replaced by some reactive BC, including inductive or capacitive loadings. The application of these loads is shown to reduce the size of the reson...

Journal: :Lab on a chip 2014
Hyoungseon Choi Chang Su Jeon Inseong Hwang Juhui Ko Saram Lee Jaebum Choo Jin-Hyo Boo Hee Chan Kim Taek Dong Chung

Detection of pathogenic bacteria requires a sensitive, accurate, rapid, and portable device. Given that lethal microbes are of various sizes, bacterial sensors based on DC (direct current) impedance on chips should be equipped with channels with commensurate cross sections. When it comes to counting and interrogation of individual bacteria on a microfluidic chip, very narrow channels are requir...

2016
R. Ghanizadeh M. Ebadian G. B. Gharehpetian

In a microgrid (MG), it is possible to have some sensitive loads that require high voltage quality. In this paper, a new technique is proposed for selective compensation of main voltage harmonics in islanded MGs. The proposed technique is capable of adjusting the compensation percentage in proportion with the existing disturbance in the sensitive load bus (SLB) and sharing the compensation work...