نتایج جستجو برای: absorbed dose measurement
تعداد نتایج: 748807 فیلتر نتایج به سال:
Background: The exposure of human being to ionize radiation from natural sources is a continuing, inescapable feature of life on earth. Direct measurement of absorbed dose rates in air has been carried out in many countries of the world during the last few decades. Such investigations can be useful for assessment of public dose rates, the performance of epidemiological studies, and kee...
The aim of the TLD pilot study was to investigate and to reduce the uncertainties involved in the measurements of absorbed dose and to improve the consistency in dose determination in the regional radiotherapy centres in Poland. The intercomparison was organized by the SSDL. It covered absorbed dose measurements under reference conditions for Co-60, high energy X-rays and electron beams. LiF po...
Introduction Gallium-67 (67Ga) has been used as a radionuclide for imaging a variety of solid tumors since 1969. Since then use of various gallium-based radiotracers has been reported. Recently, 67Ga-labeled acetylacetate bis(thiosemicarbazones) (67Ga-AATS) complex with significant tumor accumulation and fast blood clearance has been employed. Materials and Methods In this study, the absorbed d...
Two calibrated thermistors sandwiched between two insulative polyethylene films were immersed in a 30 cm cube of water having a low thermal diffusivity. The product of the specific heat of water and temperature rise gave the combined effect of the local absorbed dose and any heat defect at a position along a temperature profile produced by cobalt-60 irradiation. The dose rate was near 18 mGy/s ...
PURPOSE To report the result of independent absorbed-dose calculations based on a Monte Carlo (MC) algorithm in volumetric modulated arc therapy (VMAT) for various treatment sites. METHODS AND MATERIALS All treatment plans were created by the superposition/convolution (SC) algorithm of SmartArc (Pinnacle V9.2, Philips). The beam information was converted into the format of the Monaco V3.3 (El...
the aim of this study was the investigation of absorbed dose to the kidneys, spleen, and liver during technetium-99 m ethylene dicysteine and technetium-99 m diethylenetriaminepentaacetic acid (99mtc-ec and 99mtc-dtpa) kidney scan. patients who had been prepared for the kidney scan, were divided into two groups (groups 1 and 2). the first group (group 1) and the second group (group 2) received ...
conclusions there was no statistically significant difference in the parotid absorbed dose between spiral tomography and a panoramic radiograph (p value = 0.18). the overall results of this study were similar to other studies. results for the tube side parotid, the average absorbed doses in spiral tomography of the anterior and posterior parts of the maxilla and mandible, with the 2 mm slice th...
background: radioiodine therapy has proven to be an effective method in the treatment of patients with differentiated thyroid carcinoma after thyroidectomy. the scope of this study is to describe a method to obtain the dose of organs using medical internal radiation dosimetry (mird) method. at the end, the results of mird calculations were compared with thermoluminescent dosimeter (tld-100). ma...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید