نتایج جستجو برای: acceleration measurement

تعداد نتایج: 485297  

2014
Lingxia Li Lili Shi Yu Liu Zengshan Tian Mu Zhou

The approach of using Magnetic Angular Rate Gravity (MARG) sensor for the current multi-sensor based pedestrian navigation algorithm magnetometers is susceptible to the external magnetic interference. The result of attitude is affected by many factors, like the low-precision MEMS gyro drift and large body linear acceleration measurements. In this paper, we propose anti-jamming algorithm which i...

2014
S. Aghion O. Ahlén C. Amsler A. Ariga T. Ariga A. S. Belov K. Berggren G. Bonomi P. Bräunig J. Bremer R. S. Brusa L. Cabaret C. Canali R. Caravita F. Castelli G. Cerchiari S. Cialdi D. Comparat G. Consolati H. Derking S. Di Domizio L. Di Noto M. Doser A. Dudarev A. Ereditato R. Ferragut A. Fontana P. Genova M. Giammarchi A. Gligorova S. N. Gninenko S. Haider T. Huse E. Jordan L. V. Jørgensen T. Kaltenbacher J. Kawada A. Kellerbauer M. Kimura A. Knecht D. Krasnický V. Lagomarsino S. Lehner A. Magnani C. Malbrunot S. Mariazzi V. A. Matveev F. Moia G. Nebbia P. Nédélec M. K. Oberthaler N. Pacifico V. Petràček C. Pistillo F. Prelz M. Prevedelli C. Regenfus C. Riccardi O. Røhne A. Rotondi H. Sandaker P. Scampoli J. Storey M.A. Subieta Vasquez M. Špaček G. Testera R. Vaccarone E. Widmann S. Zavatarelli J. Zmeskal

The precise measurement of forces is one way to obtain deep insight into the fundamental interactions present in nature. In the context of neutral antimatter, the gravitational interaction is of high interest, potentially revealing new forces that violate the weak equivalence principle. Here we report on a successful extension of a tool from atom optics--the moiré deflectometer--for a measureme...

Journal: :SpringerPlus 2016
Kenshi Saho Masao Masugi

BACKGROUND Although real-time tracking of moving objects using a variety of sensor parameters is in great demand in monitoring systems, no studies have reported α-[Formula: see text]-[Formula: see text] tracking filters using simultaneous measurements including acceleration. In this report, we propose and analyze two α-[Formula: see text]-[Formula: see text] filters using acceleration measureme...

2003
Bernhard Hiller

The Ferraris principle for measurement of the relative acceleration has been known for more than 100 years. In academic works the potential of this sensor principle has been demonstrated again and again /1, 2/. But only commercial production which has been started some years ago opened up possibilities for the sensor principle in industrial applications. The simple and robust design, combined w...

Journal: :Applied optics 2009
Yu Fu Hongjian Shi Hong Miao

Measuring deformation of vibrating specimens whose dimensions are in the submillimeter range introduces a number of difficulties using laser interferometry. Normal interferometry is not suitable because of a phase ambiguity problem. In addition, the noise effect is much more serious in the measurement of small objects because a high-magnification lens is used. We present a method for full-field...

Journal: :Biomedical sciences instrumentation 2008
Jaeho Shin Costin D Untaroiu Jason R Kerrigan Jason L Forman Jeff R Crandall

Three-dimensional kinematics of body targets are frequently tracked during vehicle impact tests using instrumented cubes. While the components of linear acceleration and angular velocity are recorded in a cube local coordinate system, transformation to a global coordinate system is required to reconstruct the whole body motions. This paper presents a methodology for local-to-global kinematic tr...

2009
Maria Luisa Casalicchio Guido Perrone Alberto Vallan

Vibration tests are widely employed in many industrial fields, and in particular in aerospace industry to evaluate the mechanical behavior of parts for aircrafts and satellites. Usually, these tests are carried out with shakers, while inertial accelerometers are used to measure the shaker table acceleration from which the vibration amplitude is computed. Some applications require the measuremen...

2005
A. Castellina F. Donato

We discuss the potential of different experimental configurations directly measuring charged cosmic ray nuclei at energies 100 GeV/n. Using a two-zone diffusion model for the propagation of stable cosmic rays, we generate different predictions of the primary and secondary fluxes of light nuclei. It is shown that the new detectors exploiting the long and ultra long duration balloon technology ca...

Journal: :Prosthetics and orthotics international 1988
G R Johnson

This paper describes a study of the effectiveness of commercially available shock absorbing insoles when used in four different pairs of shoes during normal walking. The measurement method was based on the use of the Fourier Transform of the axial acceleration of the leg measured by an accelerometer mounted at the ankle. The magnitude of shock was measured by the "Shock Factor" which has been d...

2014
Li Xun

In order to estimate and get the flight attitude, trajectory, launching speed, ejection altitude, landing point, landing speed and displacement, etc. of aircraft, parameters of six degree of freedom inertial measurement unit are usually acquired to establish the settlement data base in the design and study of aircraft. Moreover, the gyro used to measure the angular rate is an important part of ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید