نتایج جستجو برای: ahmed abdol almoti hijazi

تعداد نتایج: 3346  

2015
Ayman A. Mostafa Khaled M. Ali

Objective: Safety and efficacy of Ahmed glaucoma valve implantation for the management of uveitis induced glaucoma evaluated on the five dogs with uncontrollable glaucoma. Materials and Methods: Ahmed Glaucoma Valve (AGV®; New World Medical, Rancho Cucamonga, CA, USA) is a flow restrictive, nonobstructive self-regulating valve system. Preoperative ocular evaluation included direct ophthalmoscop...

Journal: :Archives of ophthalmology 2009
Nurettin Sahiner Daniel J Kravitz Rabah Qadir Diane A Blake Salima Haque Vijay T John Curtis E Margo Ramesh S Ayyala

OBJECTIVE To create and test a slow-release antifibrotic drug-coated glaucoma drainage device using in vitro and in vivo experiments. METHODS A slow-release device incorporating mitomycin C in poly(2-hydroxyethyl methacrylate) disks was developed using redox-polymerization techniques. A standardized preparation of this drug delivery device was attached to the Ahmed glaucoma valve (model FP7; ...

Journal: :American journal of ophthalmology 2010
Nader Nassiri Ghazal Kamali Mohammad Rahnavardi Babak Mohammadi Saman Nassiri Laleh Rahmani Nariman Nassiri

PURPOSE To report 2-year follow-up data after Ahmed valve implantation (New World Medical, Inc) and Molteno single-plate implantation surgical treatment of refractory glaucoma. DESIGN Prospective, randomized, comparative study. METHODS Patients with refractory glaucoma, defined as uncontrolled intraocular pressure (IOP) of more than 21 mm Hg despite maximal antiglaucoma medication, previous...

Journal: :European journal of ophthalmology 2007
A Lanzagorta-Aresti J L Menezo-Rozalen R Martínez-Costa A Cisneros-Lanuza

PURPOSE To evaluate the Ahmed valve for decrease elevated pressure associated with black diaphragm lenses for aniridia. METHODS Drainage devices are useful to obtain good control of intraocular pressure in patients with aniridia and the authors often use them because of the poor results of medical therapy or filtering surgery. However, when the elevated intraocular pressure is associated with...

2014
Alejandra Hernandez-Oteyza Gabriel Lazcano-Gomez Jesus Jimenez-Roman Carlos Hernandez-Garciadiego

PURPOSE To describe clinical results of Ahmed glaucoma valve implantation in Mexican patients with neovascular glaucoma (NVG). MATERIALS AND METHODS We reviewed records of 60 eyes of 60 patients with NVG who underwent Ahmed valve implantation, with a follow-up period of 1 year. We identified successful and failed cases and compared baseline and follow-up characteristics to identify possible d...

2017
Ilya Sluch Brett Gudgel Justin Dvorak Mary Anne Ahluwalia Kai Ding Steve Vold Steven Sarkisian

Aim To evaluate the safety and efficacy of the M4 (porous polyethylene plate) Ahmed Glaucoma Valve (AGV) drainage implant in a multicenter retrospective study. Materials and methods A retrospective chart review of medical records of patients who had undergone the M4 Ahmed valve was performed from January 2013 to April 2015. The primary outcome measure was surgical failure defined as: Less tha...

Journal: :Archivos de la Sociedad Espanola de Oftalmologia 2012
J Moreno-Montañés E de Nova E Bonet Farriol

rainage devices are an efficient surgical treatment for esistant glaucoma or when previous filtrating surgery fails. here are 2 types of these devices: those comprising valves, n which the device includes a restriction at the outlet of he aqueous, and devices without valves in which the tube onnects with a dish without any type of restriction. Of the ormer, the best known is the Ahmed implant, ...

2017
Ivano Riva Gloria Roberti Francesco Oddone Anastasios GP Konstas Luciano Quaranta

Implantation of Ahmed glaucoma valve is an effective surgical technique to reduce intraocular pressure in patients affected with glaucoma. While in the past, the use of this device was reserved to glaucoma refractory to multiple filtration surgical procedures, up-to-date mounting experience has encouraged its use also as a primary surgery for selected cases. Implantation of Ahmed glaucoma valve...

Journal: :The British journal of ophthalmology 2000
J S Lai A S Poon J K Chua C C Tham A T Leung D S Lam

AIMS To evaluate the efficacy and safety of the Ahmed glaucoma valve implant in Chinese eyes with complicated glaucomas. METHODS This retrospective study reviewed the final intraocular pressure, visual outcome, and incidence of complications in all patients with the Ahmed glaucoma valve implant performed at the Prince of Wales Hospital, Hong Kong, between June 1996 and November 1998. RESULT...

2012
Osama Mohamed Ahmed Ahmed M. Hussein Rasha Rashad Ahmed

Synthesis of some novel pyrimido[1,6-a]pyrimidine derivatives 4, 8 and 10 was described through the respective reactions of sodium salts of formyl ketones 1, 7 and 9 with 6-aminothiouracil. The characterization of the reaction products was confirmed by using the available elemental analysis and spectral data. One of these derivatives (4b), 1-thioxo-1,2,7,8,9,10-hexahydro-3H-pyrimido[1,6-a]quina...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید