نتایج جستجو برای: biodegradable alloy corrosion hydroxyapatite sputtering

تعداد نتایج: 108831  

2014
Leonardo P. Faverani Wirley G. Assunção Paulo Sérgio P. de Carvalho Judy Chia-Chun Yuan Cortino Sukotjo Mathew T. Mathew Valentim A. Barao

Diabetes and infections are associated with a high risk of implant failure. However, the effects of such conditions on the electrochemical stability of titanium materials remain unclear. This study evaluated the corrosion behavior of a Ti-6Al-4V alloy, with a smooth surface or conditioned by double-acid-etching, in simulated body fluid with different concentrations of dextrose and lipopolysacch...

Journal: :Dental materials journal 2012
Guangyan Qiao Jiansheng Su Meifeng He

The aim of this study was to investigate the electrochemical behavior of Co-Cr alloy in artificial saliva containing (-)-epigallocatechin gallate (EGCG) and to characterize the composition and structure of the passive film formed by potentiodynamic polarization.Electrochemical measurements ranked the corrosion resistance of Co-Cr dental cast alloy as follows when exposed to artificial saliva co...

2013
M. Pakshir M. R. Kazemi

Orthodontic mechanotherapy encompasses the use of several archwires during speci c stages of treatment. Metallic orthodontic appliances consist of bands, arch wires, ligature wires, hooks, tubes, brackets, and springs are daily used in orthodontic practices for the correction of malocclusions in patients ( Oh et al. , 2004 ; Verstrynge et al. , 2006 ; Sabane et al. , 2009 ). One of the most im...

2015
Yu Zuo Shiwen Wang Yuming Tang Yong Zhou

The inhibition mechanism of sodium oleate (C17H33COONa) for pitting corrosion of aluminum alloy (AA) 2024 in 0.1 mol L NaCl solution was investigated using potentiodynamic polarization, electrochemical impedance spectroscopy (EIS), scanning electron microscopy with energy dispersive spectrometer (SEM-EDS) and X-ray photoelectron spectroscopy (XPS). C17H33COONa showed good inhibition effect on u...

Journal: :Dental materials : official publication of the Academy of Dental Materials 2011
B B Zhang B L Wang L Li Y F Zheng

OBJECTIVES The aim of the present study was to investigate the effect of thermal oxidation on the corrosion behavior of Ti-5Ag alloy. METHODS The microstructure of Ti-5Ag alloy without and with thermal oxidization treatment were characterized, with commercial pure (CP) Ti as control, by means of X-ray diffraction (XRD), X-ray photoelectron spectroscopy (XPS) and scanning electron microscopy (...

2013
Deepa Prabhu

The corrosion behaviour of aluminium and6063 aluminium alloy was investigated in phosphoric acid of different concentrations at different temperatures. The study was done by electrochemical method, using Tafel polarization and electrochemical impedance spectroscopy (EIS) techniques. The kinetic parameters and thermodynamic parameters were calculated using Arrhenius theory and transition state t...

Aluminum alloys such as Al 5083 have primary potential for lightweight structural application in automotive and aerospace industries. This paper addresses the mechanical and tribological properties and corrosion resistance of chromium nitride coatings deposited on Al 5083 that can be used for development of applications of aluminum 5083 alloy. The CrN coatings of 1 μm thickness were deposited b...

2009
VictoR M. PaNtoJaS

address correspondence to: Dr. Victor Pantojas, Math-Physics Department, Universidad de Puerto Rico en cayey, 205 ave. antonio R. Barceló, cayey, PR 00736. Tel: (787) 738 2162 ext. 3257 • E-mail: [email protected] Scaffolds composed of a mixture of poly (L-lactic) acid (PLLA) and polyethylene glycol (PEG) biodegradable polymers were prepared by electrospinning. Threedimensional scaffolds ...

2007
Masafumi Morita Tokiko Hashimoto Kiyoshi Yamauchi Yuji Suto Takayuki Homma Yuji Kimura

This study was conducted to evaluate the biocompatibility of titanium-nickel shape memory alloy used as a medical implant material. The authors carried out the following electrochemical corrosion test and in vivo and in vitro biological tests for the alloy and some metal and alloys clinically used previously to compare the intensities concerned with the biological reactions, that is, (1) anodic...

Journal: :The Journal of bone and joint surgery. British volume 1992
G L Maistrelli N Mahomed D Garbuz V Fornasier I J Harrington A Binnington

In 33 dogs we implanted femoral stems made either of carbon composite, some coated with hydroxyapatite, or of titanium alloy with a porous coating. Osseointegration was greater in the hydroxyapatite-coated than in the un-coated stems (p less than 0.001). Push-out tests, at an average of 7.2 months after implantation, showed a six-fold increase in interface shear strength and a twelve-fold incre...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید