نتایج جستجو برای: catheter ablation
تعداد نتایج: 83948 فیلتر نتایج به سال:
BACKGROUND A high ablation success rate for ventricular arrhythmia (VA) from outflow tract has been achieved, but some of them cannot be eliminated from endocardium. We investigated the association between adenosine sensitivity and ablation success/recurrence rates with a nonirrigated or an irrigated catheter. METHODS According to adenosine test, all patients were divided into a sensitive gro...
AIMS A new remote catheter system (AMIGO™ Remote Catheter System) compatible with conventional ablation catheters is now commercially available but no data about its performance in clinical use during ablation have been reported. This study evaluates the feasibility, efficacy, and safety of cavo-tricuspid isthmus (CTI) ablation with this system in patients with typical atrial flutter (AFl). M...
Lesion size during radiofrequency catheter ablation in patients with paroxysmal supraventricular tachycardia (PSVT) is thought to be related to multiple factors, including contact pressure at the catheter-endocardial interface. Therefore a predictor of contact pressure at a potential target site for ablation might be useful. In this study 25 patients underwent duplicate 2 W applications of radi...
Background: This study assessed the efficacy and safety of techniques used to ablate left-sided accessory atrioventricular pathways at atrial insertion sites by retrograde aortic approach. Radiofrequency catheter ablation of left-sided accessory pathways by way of retrograde aortic approach can be highly successful. Methods: This study were done in the department of Cardiology, National Institu...
Ventricular tachycardia (VT) in the setting of structural heart disease (SHD) and a reduced ejection fraction (EF) of ≤35% is commonly treated by insertion of an implantable cardioverter-defibrillator (ICD). While the strategy of secondary prevention reduces mortality, the presence of an ICD has no impact on recurrent episodes of VT. Hence, antiarrhythmic drug therapy is frequently established ...
Normal 0 false false false EN-US X-NONE AR-SA MicrosoftInternetExplorer4 /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal" mso-tstyle-rowband-size:0 mso-tstyle-colband-size:0 mso-style-noshow:yes mso-style-priority:99 mso-style-qformat:yes ms...
A 63-year-old man with a history of remote inferior myocardial infarction and coronary artery bypass grafting (CABG) underwent catheter ablation of ventricular tachycardia (VT). Epicardial catheter ablation of the VT was successful at the crux of the heart despite limited mapping within the pericardial space due to pericardial adhesion. Percutaneous subxiphoidal pericardial approach is usually ...
In the past years, catheter ablation has evolved into an effective treatment option for symptomatic, drug-resistant atrial fibrillation (AF) and it has recently been implemented as a primary treatment strategy for patients with paroxysmal AF. Although a significant number of studies have evaluated the potential benefits of catheter ablation compared with anti-arrhythmic drug (AAD)-therapy, to d...
The number of atrial fibrillation (AF) catheter ablations performed annually has been increasing exponentially in the western countries in the last few years. This is clearly related to technological advancements, which have greatly contributed to the improvements in catheter ablation of AF. In particular, state-of-the-art electroanatomical mapping systems have greatly facilitated mapping proce...
Sustained ventricular tachycardia (VT) in patients with advanced cardiomyopathy is a potentially life-threatening arrhythmia. Newer treatment strategies have evolved that combine the use of catheter ablation to target the substrate for VT and ventricular assist devices (VADs) to hemodynamically support the failing ventricle. This editorial is targeted to the practicing clinician caring for thes...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید