نتایج جستجو برای: computed tomography phantom

تعداد نتایج: 279342  

Journal: :Indonesian Journal of Electrical Engineering and Computer Science 2023

This study aims to evaluate the automated measurement of slice sensitivity profile (SSP) on American Association Physicists in Medicine (AAPM) computed tomography (CT) performance phantom for variations thickness and field view (FOV). The AAPM CT was scanned using a Philips MRC 880 Scanner FOV. values were 1, 3, 5 mm. FOV 240, 300, 340, 400, 440 SSPs their fullwidth at half maximums (FWHMs) aut...

Journal: :iranian journal of radiology 0
fariba rezaeetalab department of pulmonary medicine, m}oo vm{ea{ospi~el bmsw{mavc}nkwovw{ yiogmmwe{calossiuoomsmashhad university of medical sciences,, iran +98-5118598818, [email protected]; department of pulmonary medicine, m}oo vm{ea{ospi~el bmsw{mavc}nkwovw{ yiogmmwe{calossiuoomsmashhad university of medical sciences,, iran +98-5118598818, [email protected] donya farrokh department of radiology, imam reza hospital, mashhad university of medical sciences, iran

Journal: :iranian red crescent medical journal 0
vahid noorian department of general surgery, medical school, shahid beheshti university of medical sciences, iran +98-9122158199, [email protected]; department of general surgery, medical school, shahid beheshti university of medical sciences, iran +98-9122158199, [email protected] arya motaghi department of radiology, medical school, shahid beheshti university of medical sciences, iran

background paranasal sinus ct has high sensitivity and specificity for sinusitis. however, this modality is costly and involves greater radiation exposure than plain radiographs. objectives we tried to compare 10-cut limited ct scan and standard ct scan in the diagnosis of sinusitis. materials and methods we conducted a cross sectional case series from august to december 2010 on 150 patients wi...

2012
Alain Seret Daniel Nguyen Claire Bernard

BACKGROUND Four state-of-the-art single-photon emission computed tomography-computed tomography (SPECT-CT) systems, namely Philips Brightview, General Electric Discovery NM/CT 670 and Infinia Hawkeye 4, and Siemens Symbia T6, were investigated in terms of accuracy of attenuation and scatter correction, contrast recovery for small hot and cold structures, and quantitative capabilities when using...

Journal: :Applied optics 2003
Adam Gibson Roza Md Yusof Hamid Dehghani Jason Riley Nick Everdell Robin Richards Jeremy C Hebden Martin Schweiger Simon R Arridge David T Delpy

We have begun clinical trials of optical tomography of the neonatal brain. To validate this research, we have built and imaged an anatomically realistic, tissue-equivalent neonatal head phantom that is hollow, allowing contrasting objects to be placed inside it. Images were reconstructed by use of two finite-element meshes, one generated from a computed tomography image of the phantom and the o...

2002
Graham R Davis

Analytical phantoms are used to generate projection data for testing reconstruction accuracy in computed axial tomography. A circular source locus (equivalent to rotating specimen with a fixed source) provides insufficient data for ‘exact’ reconstruction in cone-beam transmission tomography, thus phantom data are useful for studying the consequent errors and also for investigating alternative s...

Jalil Pirayesh Islamian, Mahnaz Amini Masoud Pezeshkirad Negar Moro vatdar SeiedehFatemeh Ayatifard

Introduction: Important complications of venous thromboembolism (VTE) are a longer hospital stay, readmission, recurrence of the emboli, complications of anticoagulant therapy and death in a sever condition. In present study, the volume measurement accuracy of the medical imaging interaction toolkit (MITK) software on determining VTE in computed tomography images was evaluated....

2015
A. Janbabanezhad Toori A. Shabestani-Monfared M.R. Deevband R. Abdi M. Nabahati

BACKGROUND Medical X-rays are the largest man-made source of public exposure to ionizing radiation. While the benefits of Computed Tomography (CT) are well known in accurate diagnosis, those benefits are not risk-free. CT is a device with higher patient dose in comparison with other conventional radiation procedures. OBJECTIVE This study is aimed at evaluating radiation dose to patients from ...

Journal: :iranian journal of radiology 0
hilal sahin department of radiology, faculty of medicine, ege university, 35100, turkey +90-2323902202, [email protected]; department of radiology, faculty of medicine, ege university, 35100, turkey +90-2323902202, [email protected] naim ceylan department of radiology, faculty of medicine, ege university, 35100, turkey +90-2323902202, [email protected] selen bayraktaroglu department of radiology, faculty of medicine, ege university, 35100, turkey +90-2323902202, [email protected] sezai tasbakan department of pulmonology, faculty of medicine, ege university, turkey ali veral department of pathology, faculty of medicine, ege university, turkey recep savas department of radiology, faculty of medicine, ege university, 35100, turkey +90-2323902202, [email protected]

abstract necrotizing sarcoid granulomatosis (nsg) is a rare disease which is classified in the spectrum of pulmonary angiitis and granulomatosis. it is a variant of sarcoidosis and differs from it histologically. diagnosis is based on the pathological features, but radiology may help in the differential diagnosis. it is characterized by alveolar infiltrates or parenchymal nodules in multidetect...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید