We have repeated the experiment of Taleyarkhan et al. in an attempt to detect the emission of neutrons from d-d fusion during bubble collapse in deuterated acetone. Using the same apparatus, a more sophisticated data acquisition system, and a larger scintillator detector, we find no evidence for 2.5-MeV neutron emission correlated with sonoluminescence from the collapsing bubbles. Any neutron e...