نتایج جستجو برای: friction resistance

تعداد نتایج: 407246  

2015
Azam Pasha Swati Vishwakarma Anjali Narayan K Vinay Smitha V Shetty Partha Pratim Roy

BACKGROUND Fixed orthodontic mechanotherapy is associated with friction between the bracket - wire - ligature interfaces during the sliding mechanics. A sound knowledge of the various factors affecting the magnitude of friction is of paramount importance. The present study was done to analyze and compare the frictional forces generated by a new ceramic (Clarity Advanced) bracket with the conven...

2015
Valiollah Arash Saeed Javanmard Zeinab Eftekhari Manouchehr Rahmati-Kamel Mohammad Bahadoram

This research aimed to reduce the friction between the wire and brackets by Er:YAG laser. To measure the friction between the wires and brackets in 0° and 10° of wire angulations, 40 polycrystalline ceramic brackets (Hubit, South Korea) were divided into 8 study groups and irradiated by 100, 200, and 300 mj/s of Er:YAG laser power. Two groups of brackets were not irradiated. The friction betwee...

2018
Qingqiang Chen Zhihao Zhao Qingfeng Zhu Gaosong Wang Kai Tao

In this study, the effects of cerium (Ce) addition on the friction and wear properties of surface welding AZ91 magnesium alloys were evaluated by pin-on-disk dry sliding friction and wear tests at normal temperature. The results show that both the friction coefficient and wear rate of surfacing magnesium alloys decreased with the decrease in load and increase in sliding speed. The surfacing AZ9...

2007
C. D. Foster R. I. Borja R. A. Regueiro R. A. REGUEIRO

The strong discontinuity approach to modelling strain localization, combined with an enhanced strain element, has been used for more than a decade to model strain localization in materials including geomaterials. Most implementations of enhanced strain elements in the post-localization regime use very simple constitutive formulations along the discontinuity, such as linear softening or a consta...

2010
Patrick M. Fulton Robert N. Harris Demian M. Saffer Emily E. Brodsky

[1] Knowledge of frictional resistance along faults is important for understanding the mechanics of earthquakes and faulting. The clearest in situ measure of fault friction potentially comes from temperature measurements in boreholes crossing fault zones within a few years of rupture. However, large temperature signals from frictional heating on faults have not been observed. Unambiguously inte...

2005
M. Bahrami M. M. Yovanovich J. R. Culham

The characteristics of fully-developed, laminar, pressure-driven, incompressible flow in rough circular microchannels are studied. A novel analytical model is developed that predicts the increase in pressure drop due to wall roughness in microtubes. The wall roughness is assumed to posses a Gaussian isotropic distribution. The present model is compared with experimental data, collected by other...

Journal: :Langmuir : the ACS journal of surfaces and colloids 2005
D M Rampulla C M Mancinelli I F Brunell A J Gellman

The origins of the tribological properties and corrosion resistance of amorphous and quasicrystalline approximant alloys have been studied by comparing their properties in thin Al-Cu-Fe alloy films with compositions lying near the quasicrystalline region of the ternary compositional phase diagram. Six sputtered thin films of an Al-Cu-Fe alloy were studied using X-ray diffraction, X-ray photoemi...

Journal: :Biomedical materials 2008
Yufeng Zheng Dong Liu Xiliang Liu Li Li

Ti-TiC-TiC/diamond-like carbon (DLC) gradient nano-composite films have been prepared on NiTi alloy substrates by the technique of plasma immersion ion implantation and deposition (PIIID) combined with plasma-enhanced chemical vapor deposition (PECVD). The influence of negative bias voltage applied to the substrate (from -100 V to -500 V) on the chemical structure, microstructure, mechanical pr...

Journal: :The Journal of bone and joint surgery. British volume 2010
L Hajipour A Gulihar J Dias

We carried out lacerations of 50%, followed by trimming, in ten turkey flexor tendons in vitro and measured the coefficient of friction at the tendon-pulley interface with loads of 200 g and 400 g and in 10 degrees , 30 degrees, 50 degrees and 70 degrees of flexion. Laceration increased the coefficient of friction from 0.12 for the intact tendon to 0.3 at both the test loads. Trimming the lacer...

Journal: :Journal of biomedical materials research. Part B, Applied biomaterials 2010
Angela L Bruck K S Kanaga Karuppiah Sriram Sundararajan Jun Wang Zhiqun Lin

In this study, the friction and wear behavior of ultrahigh molecular weight polyethylene (UHMWPE) were evaluated as a function of polymer crystallinity in the presence of the phospholipid dipalmitoyl phosphatidylcholine (DPPC) dissolved in ethanol. Samples of UHMWPE were separately heat treated to get high and low crystallinity samples. Degree of crystallinity was evaluated using differential s...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید