Journal: :Medical physics 2000
G I Kaplan A B Rosenfeld B J Allen J T Booth M G Carolan A Holmes-Siedle

Measurement of the lateral profile of the dose distribution across a narrow x-ray microbeam requires a dosimeter with a micron resolution. We investigated the use of a MOSFET dosimeter in an "edge-on" orientation with the gate insulating oxide layer parallel to the direction of the beam. We compared results using this technique to Gafchromic film measurements of a 200 micrometer wide planar x-r...

2015
Inhwan J. Yeo Anthony Teran Abiel Ghebremedhin Matt Johnson Baldev Patyal

Radiographic film dosimetry suffers from its energy dependence in proton dosimetry. This study sought to develop a method of measuring proton beams by the film and to evaluate film response to proton beams for the constancy check of depth dose (DD). It also evaluated the film for profile measurements. To achieve this goal, from DDs measured by film and ion chamber (IC), calibration factors (rat...

Journal: :Radiation Physics and Chemistry 2021

Tissue-equivalent phantoms are suitable tools for radiation dosimetry investigations. The goal of this study was to determine the scattered dose in a simple phantom model mouse with xenographic tumour using experimental measurements and Monte-Carlo calculations. We manufactured cubic polymethyl methacrylate (PMMA) an extrusion on its side both normal tissue xenograft tumour-bearing mouse. posit...

Journal: :Radiation protection dosimetry 2017
David Welch Gerhard Randers-Pehrson Henry M Spotnitz David J Brenner

Measurement of ultraviolet (UV) radiation is important for human health, especially with the expanded usage of short wavelength UV for sterilization purposes. This work examines unlaminated Gafchromic EBT3 film for UV radiation monitoring. The authors exposed the film to select wavelengths in the UV spectrum, ranging from 207 to 328 nm, and measured the change in optical density. The response o...

Journal: :Medical physics 2005
Asa Palm Thomas LoSasso

The energy dependence of radiographic film can introduce dosimetric errors when evaluating photon beams. The variation of the film response, which is attributed to the changing photon spectrum with depth and field size, has been the subject of numerous publications in recent years. However, these data show large unexplained differences in the magnitude of this variation among independent studie...

2001
Indra J. Das Chee-Wai Cheng Sujatha Pai

Das/Cheng/Pai/AAPM//2002 Historical Perspective 1826 Joseph Niepce First Photograph 1836 J. M. Daguerre Concept of developer 1889 Eastman Kodak Cellulose nitrate base for emulsion 1890 Hurter &Driffield Defined the term optical density 1895 Roentgen First Radiograph 1896 Carl Schlussner First glass plate for radiography 1913 Kodak Film on Cellulose nitrate base 1918 Kodak Double emulsion film 1...

2007
Martina Fuss Eva Sturtewagen Carlos De Wagter Dietmar Georg

The suitability of radiochromic EBT film was studied for high-precision clinical quality assurance (QA) by identifying the dose response for a wide range of irradiation parameters typically modified in highly-conformal treatment techniques. In addition, uncertainties associated with varying irradiation conditions were determined. EBT can be used for dose assessment of absorbed dose levels as we...

2008
Peter L. Roberson Jean M. Moran Ravi Kulasekere

Radiographic film dosimetry provides fast, convenient 2-D dose distributions, but is challenged by the dependence of film response on scatter conditions (i.e., energy dependence). Verification of delivered dose in the surface buildup region is important for intensity modulated radiation therapy (IMRT) when volumes of interest encroach on these regions (e.g., head/neck, breast). The current work...

Journal: :iranian journal of medical physics 0
reza moghadam-drodkhani m.sc. in medical physics, medical physics and engineering dept., faculty of medicine, tehran university of medical sciences, tehran, iran nader riyahi-alam professor, medical physics and engineering dept., faculty of medicine, tehran university of medical sciences, tehran, iran abbas takavar professor, medical physics and engineering dept., faculty of medicine, tehran university of medical sciences, tehran, iran kavous firoznia associate professor, radiology dept., imaging center of imam khomeini hospital, faculty of medicine, tehran university of medical sciences, tehran, iran peiman hadad associate professor, radiotherapy dept., imam khomeini hospital, faculty of medicine, tehran university of medical sciences, tehran, iran behrooz rafiee m.sc., radiology dept., imaging center of imam khomeini hospital, faculty of medicine, tehran university of medical sciences, tehran, iran

introduction: the conventional methods of dosimetry are not capable of dosimetry in such a small volume of less than one cubic millimeter. although the polymer gel dosimetry method based on magnetic resonance imaging (mri) could achieve three dimensional dosimetry with high resolution, a spatial resolution evaluation based on gel dose modulation transfer function has not been investigated yet. ...

Journal: :iranian journal of radiation research 0
h. pourbeigi department of nuclear research center, atomic energy organization of iran, tehran, iran a.s. meigooni department of radiation medicine, university of kentucky, usa h. ghafourian department of nuclear research center, atomic energy organization of iran r.a. koona department of radiation medicine, university of kentucky, usa m.h. zahmatkesh novin medical radiation institute, tehran, iran

abstractbackgrounds: md-55-2 is one of the radiochromic film models with the sensitivity suitable for dose measurements ranging from 5 to 100 gy.  however, this lower limit makes the film impractical for its applications in many areas such as brachytherapy source dosimetry.materials and methods: in this project, the useful range of the film has been extended by using a multilayer film technique...