نتایج جستجو برای: hip prosthesis

تعداد نتایج: 88373  

2010
Sadegh Rahmati Farzam Farahmand Farid Abbaszadeh

Recently, as the result of development in modern imaging, computerized three dimensional data processing and advanced engineering techniques, a prosthesis that match the skeletal anatomy can be accurately designed using computer aided design (CAD) where the physical model of prosthesis or skull replica can be produced through rapid prototyping (RP), rapid tooling (RT), and computer aided manufa...

Journal: :Journal of public health medicine 1996
P B Pynsent S R Carter C J Bulstrode

A computer-based model is used to investigate the total cost of primary total hip-joint replacement. The model takes into account the probability of prosthesis failure, death and re-revision. The results emphasize the importance of age at insertion, demonstrating that the expected life-span of the patient has a major influence on the total cost for a given prosthesis. The discussion considers t...

2017
N. Adhikari Dinesh Babu Pandey

1. Rana SB, Pokharel S. A dosimetric study of volumetric modulated arc therapy planning techniques for treatment of low-risk prostate cancer in patients with bilateral hip prostheses. South Asian J Cancer 2014;3:18-21. 2. Rana S, Cheng C, Zheng Y, Hsi W, Zeidan O, Schreuder N, et al. Dosimetric study of uniform scanning proton therapy planning for prostate cancer patients with a metal hip prost...

Journal: :Annals of physical and rehabilitation medicine 2011
P Bernard J-F Gonzalez J Facione J-J Chapus D Lagauche

The complications of total hip arthroplasty (THA) during the immediate postoperative period consist mainly in dislocation of the prosthesis, haematomas under antocoagulants, early infections, dismantling of osteotomy, neurological injury, heterotopic ossification and delayed restoration of the range of motion of the hip joint. We present here an infrequently described case of haematoma of the p...

Journal: :British journal of anaesthesia 1989
R D Evans M G Palazzo J W Ackers

The frequency of air embolism was studied in 21 patients during total hip replacement. Two groups were examined, one having femoral shaft cement insertion by hand, the other by Exeter cement gun. Venous air embolism was common throughout the hip surgery, but was especially so during prosthesis positioning in the femoral shaft. There were fewer air emboli and cardiovascular sequelae detected in ...

Journal: :Acta orthopaedica Belgica 2008
Adrian Skwara Simone Stracke Carsten O Tibesku Susanne Fuchs-Winkelmann

Clinical results after total hip arthroplasty with the use of a Hylamer liner have been described as being poor. In this study, polyethylene wear rates as well as clinical results were assessed after hip arthroplasty using a Hylamer liner. Thirty patients were followed radiographically and clinically after total hip arthroplasty with a Hylamer liner. The mean follow-up was six years. Radiolucen...

Journal: :Bulletin (Hospital for Joint Diseases (New York, N.Y.)) 2005
Vasfi Karatosun Izge Gunal Bayram Unver

We retrospectively evaluated the results of 61 patients (67 hips) who underwent total hip arthroplasty using the thrust plate prosthesis (TPP) for osteoarthritis of the hip joint. All patients were followed-up at least two years (mean: 37.2 months). Mean preoperative Harris hip score improved from 45.8 (SD: 13.5) to 94.9 (SD: 5.4) points postoperatively. Revision was performed in five cases. Me...

Journal: :The European respiratory journal 1989
D Galdermans D Coolen I Neetens J Bultinck G Parizel

A patient is presented with progressive respiratory failure, caused by pulmonary fat embolism as proved by an open lung biopsy. Four and a half yrs earlier, she underwent a right hip operation. We surmise that a loosening hip prosthesis caused the marrow embolisation.

2011
James W. Pritchett

The greatest concern after metal-on-metal hip resurfacing may be the development of metallosis. Metallosis is an adverse tissue reaction to the metal debris generated by the prosthesis and can be seen with implants and joint prostheses. The reasons patients develop metallosis are multifactorial, involving patient, surgical, and implant factors. Contributing factors may include component malposi...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید