نتایج جستجو برای: light interferometer

تعداد نتایج: 405541  

Journal: :Optics express 2009
He Wang Michael Chini Eric Moon Hiroki Mashiko Chengquan Li Zenghu Chang

The dependence of the carrier-envelope (CE) phase of the pulses from a hollow-core fiber on the input laser energy was studied using two f-to- 2f interferometers. The CE phase in the in-loop f-to-2f interferometer was measured with the octave spanning white-light spectrum from the hollow-core fiber, whereas the out-of-loop interferometer was based on a sapphire plate. By modulating the input po...

2011
Hernani M. Lopes Mario A. Vaz Rui M. Guedes J. F. Silva Gomes Roberto Frias

Shearography is a non-contact full field technique used in the assessment of spatial gradient of displacements through a preset direction, Hung and Taylor [1]. The optical set-up can be based on a Michelson interferometer scheme, for static or quasi-static measurements, and on the MachZehnder interferometer if dynamic measurements have to be performed, Santos et al [2]. In both set-ups a speckl...

Journal: :Clinical chemistry 1997
B H Schneider J G Edwards N F Hartman

The Hartman interferometer, a proprietary integrated optic sensor, provides a basis for a broad range of biomedical diagnostics, including antibody-based and gene probe-based assays. As with other evanescent-wave optical sensors, the interferometer measures the refractive index change resulting from biomolecular binding on a waveguide surface. The exciting promise of evanescent-wave sensors lie...

2012
Tsuyoshi AKIYAMA Ryo YASUHARA Tokihiko TOKUZAWA Mitsutaka ISOBE Kazuo KAWAHATA Kazuya NAKAYAMA Shigeki OKAJIMA

Electron density measurement remains indispensable to control fueling on a DEMO reactor. For steadystate operation of the DEMO reactor, density measurement should be highly reliable and accurate. A dispersion interferometer and a Faraday polarimeter are free from measurement errors caused by mechanical vibrations. Hence combination of the two diagnostics yields a suitable system for density mea...

Journal: :Optics letters 2011
Alireza Marandi Brian T Lantz Robert L Byer

In this Letter we show that interferometers with unbalanced arm lengths can be balanced using optical elements with appropriate group delays. For matched group delays of the arms, the balanced interferometer becomes insensitive to the frequency noise of the source. For experimental illustration, a ring resonator is employed as a slow-light element to compensate the arm-length mismatch of a Mach...

Journal: :Physical review letters 2005
Ying-Ju Wang Dana Z Anderson Victor M Bright Eric A Cornell Quentin Diot Tetsuo Kishimoto Mara Prentiss R A Saravanan Stephen R Segal Saijun Wu

An atom Michelson interferometer is implemented on an "atom chip." The chip uses lithographically patterned conductors and external magnetic fields to produce and guide a Bose-Einstein condensate. Splitting, reflecting, and recombining of condensate atoms are achieved by a standing-wave light field having a wave vector aligned along the atom waveguide. A differential phase shift between the two...

Journal: :Optics express 2010
S Slussarenko V D'Ambrosio B Piccirillo L Marrucci E Santamato

In this paper we show that an optical setup based on a polarizing Sagnac interferometer combined with a Dove prism can be used as a convenient general-purpose tool for the generation, detection and sorting of spin-orbit states of light. This device can work both in the classical and in the quantum single-photon regime, provides higher sorting efficiency and extinction ratio than usual hologram-...

2018
Mingjie Xin Wui Seng Leong Zilong Chen Shau-Yu Lan

Coherent interactions between electromagnetic and matter waves lie at the heart of quantum science and technology. However, the diffraction nature of light has limited the scalability of many atom-light-based quantum systems. We use the optical fields in a hollow-core photonic crystal fiber to spatially split, reflect, and recombine a coherent superposition state of free-falling 85Rb atoms to r...

2016
Feng Gao Dawei Tang Xiangqian Jiang

This paper presents a high speed surface profile optical measurement technique based on white light spectral interferometry and parallel signal processing using a general purpose graphic processing unit (GPGPU). A white light source is used to acquire the surface profile of the sample instantly in real time through a cylindrical Michelson interferometer. The interference signals are resolved by...

2004
S. S. Harilal M. S. Tillack

Fabrication of an interferometer is planned at the UCSD Laser Plasma and Laser-Matter Interactions Laboratory. The primary goal of this project is to measure the density at early times in the evolution of highly transient laser created plasmas. We describe the design concepts and details of different kinds of interferometer for measuring density evolution, especially during early time of plasma...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید