نتایج جستجو برای: liquid membrane electrode
تعداد نتایج: 654404 فیلتر نتایج به سال:
A PVC membrane Fe(III) ion selective electrode has been constructed using a new macrocyclic asmembrane carrier.The electrode exhibits a good potentiometric response for Fe(III) over a wideconcentration range 1.0×10-4 to 1.0×10-1M with a slope 19.4±0.5 mV/decade a and a working pHrange of 6.5-9.0. It has a fast response time ≤30s.The best performance was observed with themembrance having the 30....
A PVC ion-selective membrane electrode based on Cd-tetraphenyl porphyrine as a carrier was prepared fordetermination of MnO4- ion. This electrode revealed good selectivity toward permanganate ion over a widevariety of anions. Effects of some experimental parameters such as nature of the plasticizer, the amounts ofcarrier and additive, and concentration of the internal solution on the potential ...
A tunable-focus liquid lens using dielectrophoretic effect is demonstrated. When a voltage is applied to a dielectric liquid droplet, the generated electric field inside the droplet is inhomogeneous. As a result, the liquid bears a dielectric force and its surface profile can be reshaped which causes the focal length to change. Adaptive lenses with different apertures are fabricated and their p...
Electrical discharge machining (EDM) is well established machining technique mainly used to machine complex geometries on difficult-to-machine materials and high strength temperature resistant alloys. In the present research, the objective is to study the shape of the electrode and establish the application of liquid nitrogen in reducing distortion of the electrode during electrical discharge m...
the performances of two-phase polymer-liquid pebax®/polyethylene glycol (peg) and three-phase polymer-liquid-solid pebax®/peg/mwnt thin film composite membranes for co2 and ch4 permeation were studied. the effect of temperature and mwnt/pebax® ratio on single gas (co2 and ch4) permeability was investigated. the permeation of both gases was measured at different temperatures from 303 to 323 ˚k. ...
a novel potentiometric ion-selective pvc membrane sensor for analysis of atorvastatin (at) in pharmaceutical preparations based on atorvastatin-(tetraphenyl borate), (at-(tpb)2) as sensing element, tetraphenyl borate as additive and tris-2-ethyl-hexyl phosphate (top) as plasticizer solvent was prepared. the electrode shows a good nernestian response over the concentration range of 0.09–5586 µg ...
چکیده ندارد.
an iodide ion-selective pvc membrane sensor based on copper (π)-bis-nphenilsalicyldenaminatocomplex as a novel sensing material is successfully developed. theelectrode showed a good selectivity for iodide ion with respect to common inorganic anions. thesensor exhibited a good linear response with slope of _58.6 ± 0.4 mv per decade over theconcentration range of 5.0 × 10-6 to 1.0 × 10-1 mol l-1,...
Electrical discharge machining (EDM) is well established machining technique mainly used to machine complex geometries on difficult-to-machine materials and high strength temperature resistant alloys. In the present research, the objective is to study the shape of the electrode and establish the application of liquid nitrogen in reducing distortion of the electrode during electrical discharge m...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید