نتایج جستجو برای: membrane electrode

تعداد نتایج: 449061  

2011
M. Soledad García Joaquín A. Ortuño María Cuartero Mustafa Salem Abuherba

The construction and characterization of a new ion-selective electrode for the determination of the antipsychotic ziprasidone in mixed solvents is presented. The electrode contains a plasticized polymeric membrane based on a ziprasidone-tetraphenylborate ion-exchanger. The influence of membrane composition on the electrode response towards ziprasidone in hydroalcoholic solutions was studied. Th...

Journal: :The journal of physical chemistry. B 2006
Ju Chou Shrisudersan Jayaraman Asanga D Ranasinghe Eric W McFarland Steven K Buratto Horia Metiu

We deposit Pt particles electrochemically on an electrode covered with a Nafion membrane. Platinum ions travel through the hydrophilic channels of the membrane, and platinum deposits are formed at the place where the channels make contact with the planar electrode. This procedure deposits the catalyst only at the end of the hydrophilic channels that cross the membrane; no catalyst is placed und...

Journal: :Neuron 2008
Romain Brette Zuzanna Piwkowska Cyril Monier Michelle Rudolph-Lilith Julien Fournier Manuel Levy Yves Frégnac Thierry Bal Alain Destexhe

Intracellular recordings of neuronal membrane potential are a central tool in neurophysiology. In many situations, especially in vivo, the traditional limitation of such recordings is the high electrode resistance and capacitance, which may cause significant measurement errors during current injection. We introduce a computer-aided technique, Active Electrode Compensation (AEC), based on a digi...

2004
Ashok Kumar Singh Rupam Singh Puja Saxena

A polystyrene-based membrane of 2,10-dimethyl-4,12-diphenyl-1,5,9,13tetraazacyclohexadeca-1,4,9,12-tetraene macrocyclic ionophore was prepared and investigated as Cr(III)-selective electrode. The best performance was observed with the membrane having the polystyrene-ligand-dibutylphthalate-sodiumtetraphenyl borate composition 1:4:1:1 with a Nernstian slope of 19.0 mV per decade of concentration...

Journal: :Analytical sciences : the international journal of the Japan Society for Analytical Chemistry 2002
Abdolkarim Abbaspour Behnam Khajeh

A PVC membrane electrode for lead ions based on phenyl disulfide as the membrane carrier was developed. The electrode exhibits a good Nernstian slope of 29.3 +/- 0.7 mV/decade and a linear range of 2.0 x 10(-6)-1.0 x 10(-2) M for Pb(NO3)2. The limit of detection is 1.2 x 10(-6) M. It has a response time of 45 s and can be used for at least fifty days without any divergence in potential. The pro...

Journal: :Analytical sciences : the international journal of the Japan Society for Analytical Chemistry 2003
Demet Kuruoğlu Esin Canel Shahabuddin Memon Mustafa Yilmaz Esma Kiliç

A hydrogen ion-selective poly(vinyl chloride) membrane electrode was constructed using 5,11,17,23-tetra-tert-butyl-25,26,27,28-tetracyanomethoxycalix[4]arene as a neutral carrier. The electrode showed an apparent Nernstian response in the 2-11.5 pH range with a slope of 54.0 +/- 0.2 mV/pH at 20 +/- degrees C. This electrode showed a rapid response of the emf to changes in the pH, high ion selec...

Journal: :The Journal of General Physiology 1941
Kenneth S. Cole Howard J. Curtis

The squid giant axon was placed in a shallow narrow trough and current was sent in at two electrodes in opposite sides of the trough and out at a third electrode several centimeters away. The potential difference across the membrane was measured between an inside fine capillary electrode with its tip in the axoplasm between the pair of polarizing electrodes, and an outside capillary electrode w...

Journal: :Proceedings of the National Academy of Sciences of the United States of America 1980
R Horn J Patlak

The currents through single acetylcholine-activated channels were measured on membrane fragments that had been torn from rat muscle myotubes with patch pipettes. The membrane fragments were sealed into the pipette by using the "gigohm-seal" technique of Neher, which also permitted voltage clamp of the membrane via the patch electrode. Membrane patches were excited by sudden withdrawal of the el...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید