نتایج جستجو برای: muon

تعداد نتایج: 7546  

1998
John F. Gunion

I discuss the exciting prospects for exploring a wide range of new physics at a low-energy muon collider. The physics possibilities for muon colliders (μC’s) are enormous. An incomplete list includes: front-end physics; Z physics; Higgs physics, especially s-channel factory production; precision mW , mt measurements; deep-inelastic physics, including lepto-quarks and contact interactions; super...

حقیقت, منصور, مرتضوی, نسیم,

 The g-factor of the charged leptons has always been considered by many physicists, both experimentaly as well as theoretically. In fact the electron and muon g-factor play the main role in testing the QED as well as the standard model. Meanwhile, there is a discrepancy between the standard model prediction of the muon anomalies magnetic moment and its experimental determination as large as (25...

Journal: :Physical review letters 2013
V A Andreev T I Banks R M Carey T A Case S M Clayton K M Crowe J Deutsch J Egger S J Freedman V A Ganzha T Gorringe F E Gray D W Hertzog M Hildebrandt P Kammel B Kiburg S Knaack P A Kravtsov A G Krivshich B Lauss K R Lynch E M Maev O E Maev F Mulhauser C Petitjean G E Petrov R Prieels G N Schapkin G G Semenchuk M A Soroka V Tishchenko A A Vasilyev A A Vorobyov M E Vznuzdaev P Winter

The MuCap experiment at the Paul Scherrer Institute has measured the rate Λ(S) of muon capture from the singlet state of the muonic hydrogen atom to a precision of 1%. A muon beam was stopped in a time projection chamber filled with 10-bar, ultrapure hydrogen gas. Cylindrical wire chambers and a segmented scintillator barrel detected electrons from muon decay. Λ(S) is determined from the differ...

1998
A. Bueno M. Campanelli A. Rubbia

A medium baseline search for ν µ → ν e oscillations at a ν beam from muon decays Abstract The accurate knowledge of the ¯ ν e (ν µ) beam produced in µ − decays and the absence of ν e (¯ ν µ) contamination, make a future muon storage ring the ideal place to look for ν µ → ν e (¯ ν µ → ¯ ν e) oscillations. Using a detector capable of electron and muon identification with charge discrimination (e....

2007
K. Abe J. Hosaka T. Iida J. Kameda Y. Koshio A. Minamino C. Mitsuda M. Miura S. Moriyama M. Nakahata Y. Obayashi H. Ogawa M. Shiozawa Y. Suzuki A. Takeda Y. Takeuchi K. Ueshima I. Higuchi M. Ishitsuka T. Kajita K. Kaneyuki G. Mitsuka S. Nakayama H. Nishino A. Okada K. Okumura C. Saji Y. Takenaga S. Clark S. Desai F. Dufour E. Kearns S. Likhoded M. Litos J. L. Raaf J. L. Stone L. R. Sulak W. Wang M. Goldhaber D. Casper J. P. Cravens J. Dunmore W. R. Kropp D. W. Liu S. Mine C. Regis M. B. Smy H. W. Sobel M. R. Vagins K. S. Ganezer J. E. Hill W. E. Keig J. S. Jang J. Y. Kim I. T. Lim K. Scholberg N. Tanimoto C. W. Walter R. Wendell R. W. Ellsworth S. Tasaka G. Guillian J. G. Learned S. Matsuno M. D. Messier Y. Hayato A. K. Ichikawa T. Ishida T. Ishii T. Iwashita T. Kobayashi T. Nakadaira K. Nakamura K. Nitta Y. Oyama Y. Totsuka A. T. Suzuki M. Hasegawa K. Hiraide I. Kato H. Maesaka T. Nakaya K. Nishikawa H. Sato S. Yamamoto M. Yokoyama T. J. Haines S. Dazeley S. Hatakeyama G. W. Sullivan D. Turcan J. Cooley K. B. M. Mahn A. Habig Y. Fukuda T. Sato Y. Itow T. Koike C. K. Jung T. Kato K. Kobayashi M. Malek C. McGrew A. Sarrat R. Terri C. Yanagisawa N. Tamura M. Sakuda M. Sugihara Y. Kuno M. Yoshida S. B. Kim B. S. Yang J. Yoo T. Ishizuka H. Okazawa Y. Choi Y. Gando T. Hasegawa K. Inoue H. Ishii K. Nishijima H. Ishino M. Koshiba D. Kielczewska J. Zalipska H. G. Berns R. Gran K. K. Shiraishi A. Stachyra E. Thrane

Many astrophysical models predict a diffuse flux of high-energy neutrinos from active galactic nuclei and other extra-galactic sources. At muon energies above 1 TeV, the upward-going muon flux induced by neutrinos from active galactic nuclei is expected to exceed the flux due to atmospheric neutrinos. We have performed a search for this astrophysical neutrino flux by looking for upward-going mu...

2002
Petr Travnicek Jan Ridky

The DELPHI detector at LEP, located 100 m underground, has been used to detect the multimuon bundles by cathode readout of its hadron calorimeter and its tracking detectors (TPC, muon chambers). The experimental apparatus allows us to study muon bundles originating from primary cosmic particles with energies in the interval 10 10 eV . The cosmic events registered during the years 1999 and 2000 ...

2001
J. Poirier

Project GRAND has the capability of measuring the angle and identity of single tracks of secondary muons at ground level. The array is comprised of 64 stations each containing eight proportional wire planes with a 50 mm steel absorber plate placed above the bottom two planes in each station. The added steel absorber plate allows muon tracks to be separated from the less massive electrons. Over ...

1999
S. A. Kahn H. Guler C. Lu K. T. McDonald E. J. Prebys S. E. Vahsen

The MUCOOL facility is proposed to examine cooling techniques that could be used in a muon collider. The solenoidal beam channel before and after the cooling test section are instrumented to measure the beam emittance. This instrumentation channel includes a bent solenoid to provide dispersion and time projection chambers to measure the beam variables before and after the bend. The momentum of ...

2005
Konstantin BOROZDIN Thomas ASAKI Rick CHARTRAND Gary BLANPIED Matthew SOTTILE Kevin VIXIE Brendt WOHLBERG

Scattering muon radiography was proposed recently as a technique of detection and 3-d imaging for dense high-Z objects . High-energy cosmic ray muons are deflected in matter in the process of multiple Coulomb scattering . By measuring the deflection angles we are able to reconstruct the configuration of high-Z material in the object . We discuss the methods for information extraction from muon ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید