نتایج جستجو برای: peel and shear stresses

تعداد نتایج: 16847705  

In this article, the thermo-elastic behavior of a functionally graded simple blade subjected to the mechanical and thermal loadings is presented, applying a semi-analytical method and a variable thickness cantilever beam model. A specific temperature gradient is employed between the root and the edges of the beam. It is assumed that the mechanical and thermal properties are longitudinal directi...

2015
Gisaku Kuramochi Eduardo Borie Iara-Augusta Orsi Mariano Del Sol

BACKGROUND Adhesive systems are constantly subjected to mechanical and chemical stresses that negatively impact the integrity and durability of the dentine-adhesive interface. Despite the lack of evidence to support or reject the clinical indication for mechanical retention, the potential further contribution of these preparations to the behavior of the composite resin-sound dentine bond has be...

Journal: :Journal of biomechanics 2012
Lisha Zheng Yan Huang Wei Song Xianghui Gong Meili Liu Xiaolin Jia Gang Zhou Luoping Chen Ang Li Yubo Fan

Matrix metalloproteinase (MMP)-1, 2, with their endogenous inhibitors, tissue inhibitor of metalloproteinase (TIMP)-1, 2 are critical for extracellular matrix remodeling in human periodontal ligament (PDL) and their expression are sensitive to mechanical stresses. Shear stress as the main type of mechanical stress in tooth movement is involved in matrix turnover. However, how shear stress regul...

2009
John Ouyang

A new Ultra Violet (UV) curable solution acrylic polymer based technology has been under development for manufacturing optically clear pressure sensitive adhesives. Monomers, functional groups, and formulating components can be selected to modify and tailor product properties for specific optically clear end uses. Refractive index, outgassing, heat resistance, and humidity resistance among othe...

2015
J. Kowal S. Gungor M. E. Fitzpatrick

The contour method of residual stress measurement has recently been adapted to measure fractured, rather than cut specimens. The fracture contour method was capable of determining normal residual stresses acting prior to the planestrain failure of a large aluminium alloy forging, but shear residual stresses could not be measured (Prime et al., 2014, Eng. Fract. Mech., 116, 158-171). We demonstr...

Journal: :Atherosclerosis 1994
J E Moore C Xu S Glagov C K Zarins D N Ku

Clinically significant atherosclerosis in the human aorta is most common in the infrarenal segment. This study was initiated to test the hypothesis that flowfield properties are closely related to the localization of plaques in this segment of the arterial system. Wall shear stress was calculated from magnetic resonance velocity measurements of pulsatile flow in an anatomically accurate model o...

Journal: :international journal of advanced design and manufacturing technology 0
mohammad zaman kabir department of civil and environmental engineering, amirkabir university of technology ata hojjatkashani ph. d student , department of civil and environmental engineering, amirkabir university of technology

the aim of this research is to investigate the effect of carbon fiber reinforced polymer (cfrp) composite fabric on monotonic and fatigue behaviors of reinforced concrete beams. to control the failure occurrence, a small notch was induced at the middle span in bottom surface for all of the studied rc specimens. totally 12 beams were tested from which 6 beams tested under monotonic and 6 other t...

2009
Z. Yan

Pressure-sensitive adhesives (PSAs) are the major source of stickies in paper recycling. It is desirable that the PSA not break down into very small pieces during repulping so that it can be screened out. However, it is not clear in the literature what mechanical properties of PSAs are required to make PSAs screenable. In this study, the screenability of a range of PSAs was evaluated. The hydro...

2013
Fawzi F Al-Jassir H Fouad Othaman Y Alothman

BACKGROUND Stress shielding in the cemented hip prosthesis occurs due to the mismatching in the mechanical properties of metallic stem and bone. This mismatching in properties is considered as one of the main reasons for implant loosening. Therefore, a new stem material in orthopedic surgery is still required. In the present study, 3D finite element modeling is used for evaluating the artificia...

2013
Haiyang Zhao Zhijun Zhou Hang Dong Lin Zhang Huanlin Chen Lian Hou

The alignment of carbon nanotubes (CNT) is the fundamental requirement to ensure their excellent functions but seems to be desolated in recent years. A facile method, hot-press combined with peel-off (HPPO), is introduced here, through which CNT can be successfully vertically aligned on the polymeric membrane substrate. Shear force and mechanical stretch are proposed to be the main forces to al...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید