نتایج جستجو برای: ph electrode

تعداد نتایج: 228520  

2015
Saeed Shahrokhian Masoumeh Ghalkhani Maryam Bayat Fatemeh Ghorbani-Bidkorbeh

The voltammetric performance of edge-plane pyrolytic graphite (EPG) electrode via adsorptive stripping voltammetry was investigated for study of the electrochemical behavior of omeprazole (OMZ) in aqueous solution. The results revealed that the oxidation of OMZ is an irreversible pH-dependent process that proceeds with the transfer of one electron and one proton in an adsorption-controlled mech...

A. Islamnezhad M. Kia Sh. Shariati

In order to preparing strontium ion selective electrode 6-(4- nitropheny1)-2-pheny14, 4- dipropy1-3, 5-diaza-bicyclo [3, 1, 0] hex-2-ene (NPDBH) was used as an ionophore. This electrode responds to Sr (II)ion with a sensitivity of 28.2 ± 0.5 mV/decade over the range 1.0 x 10-6 to 1.0 Mat pH 3.0-10.0. Thelimit of detection was 2.4 x 10-7 M. The influences of membrane composition, the pH of the t...

2013
Refat F. Aglan Gehad G. Mohamed Hala A. Mohamed

A new chemically modified carbon paste electrode for cesium(I) ion determination based on potassium zinc hexacyanoferrate (PZHCF) as an ionophore was prepared. The electrode exhibits a Nernstian response for Cs(I) ions over a wide concentration range from 1 × 10 to 1 × 10 mol·L with a slope of 58 ± 0.5 mV·decade. It has a response time of about 35 s and can be used for a period of 3 months with...

2008
Sabriye Perçin Özkorucuklu Yücel Şahin Güleren Alsancak

In this work, preparation of a molecularly imprinted polymer (MIP) film and its recognition properties for sulfamethoxazolewere investigated. The overoxidized polypyrrole (OPPy) film was prepared by the cyclic voltammetric deposition of pyrrole (Py) in the presence of supporting electrolyte (tetrabutylammonium perchlorate-TBAP) with and without a template molecule (sulfamethoxazole) on a pencil...

2014
Valter Nilton Felix Ioshiaki Yogi Daniel Senday Fernando Tadeu Vannucci Coimbra David Pares Vinicius Garcia Carlos Eduardo Garcia

BACKGROUND There is a large consensus to preserve the distance of 5 cm above the proximal border of the lower esophageal sphincter (PBLES) as appropriate to the location of the electrode of the pH-metry. The main objective of this study is to determine whether placement of the electrode below the recommended location achieves a significant difference in the calculation of the DeMeester score. ...

2014
Gengchen Liu Tolga Kaya

This paper presents an application for measuring the concentration of hydrogen ion by using ion selective electrodes. By this research we hope to provide useful information and verify the feasibility of measuring the concentration of other ions in the same way for sensing sweat. In this research, a pH electrode is used to generate an electrical potential which reflects the concentration of hydr...

Journal: :international journal of environmental research 0
r. daniel centre for environment, institute of science & technology, jawaharlal nehru technological university, hyderabad- 500 080, india a.v.s. prabhakara rao centre for environment, institute of science & technology, jawaharlal nehru technological university, hyderabad- 500 080, india. department of civil engineering, indian institute of technology (iit), kanpur,india

this paper is a preliminary communication of a study on removal and recovery of heavy metalsfrom industrial waste waters using electro-coagulation (ec) technique. the larger study envisages use of solarenergy for producing the d.c. current, and simple chemical methods of standard methods in chemistry like useof hydrochloric acid, hydrogen sulfide, collection of precipitate, incineration and get...

Journal: :journal of physical & theoretical chemistry 2007
m. aghaie m. h. fekri m. giahi e. baghdar s. farhadi

in order to study the cu(ii) ion selective electrode, an optimized membrane was prepared by mixing of 30 mg of pvc powdered, 5 mg of considered ionophore, 60 mg of plasticizer and 5 mg of additive. the sensor showed a near nernstian response for cu(ii) ions over a concentration range from 1.0×0-6 –1.0×0-2 m with a slope of 28.90.5 mv per concentration decade with a working ph range of 3.5-6.3. ...

Journal: :analytical and bioanalytical chemistry research 2015
molla tefera shimelis admassie merid tessema solomon mehretie

a sensor, based on multi-wall carbon nanotubes modified glassy carbon electrode (mwcnt/gce), was developed for determination of fenitrothion. determining the surface area of mwcnt/gce showed that this surface is three times more active than that of a glassy carbon electrode. the experimental parameters, such as the amount of mwcnts, ph of the fenitrothion solution, preconcentration potential an...

2013
Ta-Jen Li Chia-Yu Lin A. Balamurugan Chung-Wei Kung Jen-Yuan Wang Chih-Wei Hu Chun-Chieh Wang Po-Yen Chen R. Vittal Kuo-Chuan Ho

A polymer/mediator composite modified glassy carbon electrode (GCE) is fabricated for electrochemical detection of iodate (IO3 ). Flavin adenine dinucleotide (FAD) is chosen as mediator for sensing iodate, and 3,4 ethylenedioxythiophene (EDOT) is chosen for entrapping FAD and forming a conducting polymeric matrix, poly(3,4 ethylenedioxythiophene) (PEDOT). The PEDOT/FAD modification layer is ele...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید