نتایج جستجو برای: phantom scatter factor

تعداد نتایج: 870740  

Journal: :Nihon Hoshasen Gijutsu Gakkai zasshi 2006
Masanori Yamada Hideki Inakoshi Takahide Hayakawa Tomio Inoue Toshifumi Kasahara Satoshi Igarashi

To more easily estimate accurate values of collimator scatter facor, S(c), we suggest a two-component saturation model that accounts for scatter from the primary collimator and flattening filter and from the collimator jaws. This model, which assumes an exponential distribution of scatter intensity, was tested by in-air measurements using a mini-phantom for 4 MV and 10 MV X-rays of a Clinac 210...

2017
Livia Tossici-Bolt John C. Dickson Terez Sera Jan Booij Susanne Asenbaun-Nan Maria C. Bagnara Thierry Vander Borght Cathrine Jonsson Robin de Nijs Swen Hesse Pierre M. Koulibaly Umit O. Akdemir Michel Koole Klaus Tatsch Andrea Varrone

BACKGROUND [123I]FP-CIT is a well-established radiotracer for the diagnosis of dopaminergic degenerative disorders. The European Normal Control Database of DaTSCAN (ENC-DAT) of healthy controls has provided age and gender-specific reference values for the [123I]FP-CIT specific binding ratio (SBR) under optimised protocols for image acquisition and processing. Simpler reconstruction methods, how...

Journal: :Physics in medicine and biology 1992
Z Liang T G Turkington D R Gilland R J Jaszczak R E Coleman

A three-dimensional reconstruction method for simultaneous compensation of attenuation, scatter and distance-dependent detector response for single photon emission computed tomography is described and tested by experimental studies. The method determines the attenuation factors recursively along each projection ray starting at the intersected source voxel closest to the detector. The method sub...

Journal: :Japanese Journal of Health Physics 2022

Background and purpose: The Japanese dose-length product (Japanese-DLP) method is currently being developed for calculation of CT shielding. purpose this study to verify the Japanese-DLP method. Methods: Scattered dose in room was measured during head, body, limbs a human body phantom under standard imaging conditions, compared with radiation calculated using Results: minimum calculated/measure...

Journal: :Journal of nuclear medicine : official publication, Society of Nuclear Medicine 1991
W G Hawkins N C Yang P K Leichner

The purpose of this study was to validate the use of the circular harmonic transform (CHT) algorithm for quantitative single-photon emission computed tomography (SPECT) with isotopes technetium-99m (99mTc) and indium-111 (111In) under clinically relevant conditions. Phantom studies were the principal tools used. Volumes of fillable organs within a tissue-equivalent anthropomorphic phantom were ...

2018
Chalinee Thanasupsombat Saowapak S Thongvigitmanee Sorapong Aootaphao Pairash Thajchayapong

The quality of images obtained from cone-beam computed tomography (CBCT) is important in diagnosis and treatment planning for dental and maxillofacial applications. However, X-ray scattering inside a human head is one of the main factors that cause a drop in image quality, especially in the CBCT system with a wide-angle cone-beam X-ray source and a large area detector. In this study, the X-ray ...

2012

PET/MRI scanner images of syringe phantoms were decay corrected and normalized for scan duration prior to analysis. The first linearity phantom image acquired during a given study session was used to convert image intensities to units of absolute activity concentration (kBq/mL). Rod image intensities from the PET/MRI image, obtained from cylindrical volumes of interest axially centered on each ...

Journal: :Physics in medicine and biology 2016
Shuo Pang Zheyuan Zhu Ge Wang Wenxiang Cong

Small-angle x-ray scatter imaging has a high intrinsic contrast in cancer research and other applications, and provides information on molecular composition and micro-structure of the tissue. In general, the implementations of small-angle coherent scatter imaging can be divided into two main categories: direct tomography and angular dispersive computerized tomography. Based on the recent develo...

Journal: :Journal of nuclear medicine : official publication, Society of Nuclear Medicine 2012
Wai-Hoi Wong Hongdi Li Hossain Baghaei Yuxuan Zhang Rocio A Ramirez Shitao Liu Chao Wang Shaohui An

UNLABELLED The dedicated murine PET (MuPET) scanner is a high-resolution, high-sensitivity, and low-cost preclinical PET camera designed and manufactured at our laboratory. In this article, we report its performance according to the NU 4-2008 standards of the National Electrical Manufacturers Association (NEMA). We also report the results of additional phantom and mouse studies. METHODS The M...

Introduction: In radionuclide imaging, object scatter is one of the major factors leading to image quality degradation. Therefore, the correction of scattered photons might have a great impact on improving the image quality. Regarding this, the present study aimed to determine the main and sub-energy windows for triple energy window (TEW) scatter correction method usin...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید