نتایج جستجو برای: pressure gauge water column manometer

تعداد نتایج: 1032637  

Journal: :Chest 1985
K L Christopher T A Neff J L Bowman D J Eberle C G Irvin J T Good

A mechanical lung was used to evaluate the pressure and flow characteristics of four demand and two continuous flow intermittent mandatory ventilation (IMV) systems. The amount of negative pressure required to initiate inspiratory flow and peak expiratory resistance were measured. The inspiratory pressure required to initiate flow in the demand mode was also compared to pressures generated in t...

2017
Arris S Tijsseling

This study presents results from detailed experiments of the two-phase pressurized flow behavior during the rapid filling of a large-scale pipeline. The physical scale of this experiment is close to the practical situation in many industrial plants. Pressure transducers, water level meters, thermometers, void fraction meters and flow meters were used to measure the two-phase unsteady flow dynam...

2004
ANTON BERGANT ANGUS R. SIMPSON ARRIS S. TIJSSELING

Column separation refers to the breaking of liquid columns in fully filled pipelines. This may occur in a water hammer event when the pressure drops to the vapor pressure at specific locations such as closed ends, high points or knees (changes in pipe slope). A vapor cavity, driven by the inertia of the parting liquid columns, will start to grow. The cavity acts as a vacuum, a low-pressure poin...

Journal: :Circulation research 1963
S L SKINNER J W MCCUBBIN I H PAGE

Methods Fasting adult mongrel dogs weighing 9 to IS kg were anesthetized with morphine sulfate (2 mg/kg subcutancously) and sodium pentobarbital (15 mg/kg intravenously) or with sodium pentobarbital alone (30 mg/kg intravenously). In some experiments the vagus-sympathetic-depressor trunks were cut. Intermittent positive pressure respiration was used unless otherwise stated. Arterial pressure wa...

Journal: :Infection and immunity 1986
S L Josephson M W Stinson S J Millar R E Cohen

Lipoteichoic acid (LTA), extracted from Streptococcus mutans 10449 by hot aqueous phenol, was partially purified by Sepharose 6B column chromatography in 0.01 M sodium acetate, pH 6.0, containing 0.25 M sodium chloride and 0.001 M EDTA. Nucleic acid and polysaccharide were precipitated from the LTA-containing column peak by the addition of 2 volumes of chloroform-methanol (1:5). The resulting s...

Journal: :Journal of pharmacological sciences 2006
Igor Petrovic Ivan Dobric Petar Drvis Drazen Shejbal Luka Brcic Alenka Boban Blagaic Lovorka Batelja Neven Kokic Ante Tonkic Stjepan Mise Tomislav Baotic Mario Staresinic Bozo Radic Ana Jakir Tihomir Vuksic Tomislav Anic Sven Seiwerth Predrag Sikiric

We report a simple novel rat model that combines prolonged esophagitis and parallel sphincters failure. The anti-ulcer gastric pentadecapeptide BPC 157, which was found to be stable in gastric juice, and is being evaluated in inflammatory bowel disease trials, is an anti-esophagitis therapy that recovers failed sphincters. Twelve or twenty months after the initial challenge (tubes sutured into ...

2013
James Traer Peter Gerstoft

Interacting ocean surface waves force water column pressure fluctuations with spectral peaks at the same frequencies of primary microseisms (PM), double-frequency microseisms (DF), and seismic hum. Prior treatment of nonlinear ocean wave interactions has focused on the DF pressure fluctuations which, in the presence of opposing waves, do not decay with depth and hence are dominant in deep water...

2015
A. Boatwright S. Hughes J. Barry

The maximum height of a siphon is generally assumed to be dependent on barometric pressure-about 10 m at sea level. This limit arises because the pressure in a siphon above the upper reservoir level is below the ambient pressure, and when the height of a siphon approaches 10 m, the pressure at the crown of the siphon falls below the vapour pressure of water causing water to boil breaking the co...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید