نتایج جستجو برای: septal occluder device
تعداد نتایج: 705866 فیلتر نتایج به سال:
We describe the interdisciplinary management of a 59-year old man with ischaemic cardiomyopathy on a HeartMate II left ventricular assist device (LVAD) and temporary right extracorporeal membrane oxygenation (ECMO) as a bridge-to-heart transplantation. He suffered refractory hypoxaemia due to massive right-to-left shunting by a patent foramen ovale (PFO), diagnosed after weaning off of temporar...
Surgical closure of ventricular septal defect is safe, however, the inherent risks associated with cardiopulmonary bypass and the potential early and late postsurgical complications including complete heart block, arrhythmias, postpericardiotomy syndrome, and rare deaths have led physicians to prefer transcatheter occlusion technique for closure of such defects. The use of Amplatzer muscular ve...
OBJECTIVE To review the safety and efficacy of the Amplatzer septal occluder for transcatheter closure of interatrial communications (atrial septal defects (ASD), fenestrated Fontan (FF), patent foramen ovale (PFO)). DESIGN Prospective study following a common protocol for patient selection and technique of deployment in all participating centres. SETTING Multicentre study representing tota...
INTRODUCTION Percutaneous closure of atrial septal defects (ASD) is becoming more frequent. PATIENTS AND METHOD From October 1997 to October 2002, 209 patients, age 0.4-70 (mean 19.5) years, were catheterized to close an ASD or patent foramen ovale (PFO). Transesophageal echocardiography was performed simultaneously in all patients. Two hundred and six patients had ASD (25 multiple ASDs) and ...
The majority of patients with congenitally corrected transposition the great arteries, also known as arteries {S,L,L} have ventricular septal defects (VSD), most commonly perimembranous VSD (pmVSD). Transcatheter device closure pmVSD in these has not been widely described. We present a case L-TGA an Amplatzer Duct Occluder II (ADOII) using deployment starting subpulmonary left ventricle. demons...
OBJECTIVE To establish the implantation technique for the atrial septal defect occluder system (ASDOS) device in an experimental animal model and to determine long term mechanical stability of the device and its in vivo properties in terms of biocompatibility and tissue reaction. MATERIALS AND METHODS An atrial septal defect was created and the device implanted in 17 pigs (mean weight 30 kg)....
BACKGROUND Percutaneous occlusion of secundum type atrial septal defect with an Amplatzer device is an effective treatment alternative. However, there is little information about the use of this treatment for large defects. PATIENTS AND METHOD We retrospectively analyzed the initial and follow-up findings in 31 patients aged 41 18 years who had large atrial septal defects (>= 30 mm diameter)....