نتایج جستجو برای: septal occluder device

تعداد نتایج: 705866  

Journal: :Interactive cardiovascular and thoracic surgery 2015
Quentin Fischer Matthias Kirsch Eric Brochet Jean-Michel Juliard

We describe the interdisciplinary management of a 59-year old man with ischaemic cardiomyopathy on a HeartMate II left ventricular assist device (LVAD) and temporary right extracorporeal membrane oxygenation (ECMO) as a bridge-to-heart transplantation. He suffered refractory hypoxaemia due to massive right-to-left shunting by a patent foramen ovale (PFO), diagnosed after weaning off of temporar...

Journal: :Archives of Iranian medicine 2007
Majid Dehghani Mohammad-Bagher Sharifkazemi Amir Aslani Ehsan Hoseini Mohammad-Mehdi Samin

Surgical closure of ventricular septal defect is safe, however, the inherent risks associated with cardiopulmonary bypass and the potential early and late postsurgical complications including complete heart block, arrhythmias, postpericardiotomy syndrome, and rare deaths have led physicians to prefer transcatheter occlusion technique for closure of such defects. The use of Amplatzer muscular ve...

Journal: :Heart 1999
K C Chan M J Godman K Walsh N Wilson A Redington J L Gibbs

OBJECTIVE To review the safety and efficacy of the Amplatzer septal occluder for transcatheter closure of interatrial communications (atrial septal defects (ASD), fenestrated Fontan (FF), patent foramen ovale (PFO)). DESIGN Prospective study following a common protocol for patient selection and technique of deployment in all participating centres. SETTING Multicentre study representing tota...

Journal: :Revista espanola de cardiologia 2003
Jacek Bialkowski Jacek Kusa Malgorzata Szkutnik Zbigniew Kalarus Pawel Banaszak Ramón Bermúdez-Cañete Luis Fernández Pineda Marian Zembala

INTRODUCTION Percutaneous closure of atrial septal defects (ASD) is becoming more frequent. PATIENTS AND METHOD From October 1997 to October 2002, 209 patients, age 0.4-70 (mean 19.5) years, were catheterized to close an ASD or patent foramen ovale (PFO). Transesophageal echocardiography was performed simultaneously in all patients. Two hundred and six patients had ASD (25 multiple ASDs) and ...

Journal: :Congenital Heart Disease 2022

The majority of patients with congenitally corrected transposition the great arteries, also known as arteries {S,L,L} have ventricular septal defects (VSD), most commonly perimembranous VSD (pmVSD). Transcatheter device closure pmVSD in these has not been widely described. We present a case L-TGA an Amplatzer Duct Occluder II (ADOII) using deployment starting subpulmonary left ventricle. demons...

Journal: :Heart 1998
A Bloch Thomsen M Schneider U Baandrup E V Stenbøg J M Hasenkam J P Bagger G Hausdorf

OBJECTIVE To establish the implantation technique for the atrial septal defect occluder system (ASDOS) device in an experimental animal model and to determine long term mechanical stability of the device and its in vivo properties in terms of biocompatibility and tissue reaction. MATERIALS AND METHODS An atrial septal defect was created and the device implanted in 17 pigs (mean weight 30 kg)....

Journal: :Revista espanola de cardiologia 2003
Marcos Rodríguez José Suárez de Lezo Manuel Pan Miguel Romero José Segura Djordje Pavlovic Juan Muñoz Manuel Franco José R Ortega Alfonso Medina

BACKGROUND Percutaneous occlusion of secundum type atrial septal defect with an Amplatzer device is an effective treatment alternative. However, there is little information about the use of this treatment for large defects. PATIENTS AND METHOD We retrospectively analyzed the initial and follow-up findings in 31 patients aged 41 18 years who had large atrial septal defects (>= 30 mm diameter)....

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید