The 6 MV flattening filter-free (FFF) beam has been commissioned for use with compensators at our institution. This novel combination promises advantages in mitigating tumor motion due to the reduced treatment time made possible by the greatly increased dose rate of the FFF beam. Given the different energy spectrum of the FFF beam and the beam hardening effect of the compensator, the accuracy o...
Attenuation correction is very important for quantitative SPECT imaging. We designed an uncollimated non-uniform line array source (non-uniform LAS) for attenuation correction based on transmission computed tomography (TCT) using Tc-99m and compared its performance with an uncollimated uniform line array source (uniform LAS) in a thorax phantom study. This non-uniform LAS was attached to one ca...
The interaction of a helical antenna, mounted on a mobile handset, with a human head phantom is investigated in this paper. Using the Genetic Algorithms (GA) technique combined with the Method of Moments (MoM), an optimization of the antenna structure is achieved regarding the input impedance at the operating frequency. The Finite Difference Time Domain (FDTD) method is then applied to simulate...
For head computed tomography (CT), non-helical scanning has been recommended even in the widely used multi-slice CT (MSCT). Also, an acute stroke imaging standardization group has recommended the non-helical mode in Japan. However, no detailed comparison has been reported for current MSCT with more than 16 slices. In this study, we compared the non-helical and helical modes for head CT, focusin...
A special acrylic phantom designed for both magnetic resonance imaging (MRI) and computed tomography (CT) was used to assess the geometric accuracy of MRI-based stereotactic localization with the Leksell stereotactic head frame and localizer system. The acrylic phantom was constructed in the shape of a cube, 164 mm in each dimension, with three perpendicular arrays of solid acrylic rods, 5 mm i...
*Corresponding author: Dr. Tayyeb Allahverdi Pourfallah, Department of Medical Physics and Biomedical Engineering, Tehran University of Medical Sciences, Tehran, Iran. Fax: +98 21 88973653 E-mail: [email protected] Background: Polymer gel dosimetry is still the only dosimetry method for direct measuring of threedimensional dose distributions. MRI Polymer gel dosimeters are tissue equi...
The aim of this study was to demonstrate how dosimetry with an amorphous silicon electronic portal imaging device (a-Si EPID) replaced film and ionization chamber measurements for routine pre-treatment dosimetry in our clinic. Furthermore, we described how EPID dosimetry was used to solve a clinical problem. IMRT prostate plans were delivered to a homogeneous slab phantom. EPID transit images w...
Spatial reproduction in a conventional stereophonic audio system (e.g., stereo or 5.1 surround) works in a small area known as the ”sweet spot“. If the listener changes his position, the phantom source moves in the same direction and finally collapses into the nearer loudspeaker. A play-back system that adjusts the loudspeaker signals depending only on the listener’s position in real-time was e...
PURPOSE To evaluate the effect of objects moving outside the field of view on functional MR imaging. METHODS Echo-Planar image sequences were acquired in the sagittal plane of a stationary phantom or of the head of a volunteer subject while a second phantom was moved periodically outside the field of view. The signal intensity changes in each pixel within the field of view were measured. RE...