نتایج جستجو برای: soft tissue insertion

تعداد نتایج: 1050885  

Journal: :Acta otorrinolaringologica espanola 2015
Patricia Martínez Fernando López Justo Ramón Gómez

INTRODUCTION AND OBJECTIVES The standard surgical technique for osseointegrated hearing aids involves removing a large area of subcutaneous tissue down to the periosteum. Recently, the industry has designed a new range of abutment lengths for less invasive surgery with soft tissue preservation. This study compared and evaluated the complications in the standard and the tissue preservation techn...

Journal: :Journal of orthopaedic trauma 2006
Steven J Morgan Kim Furry Anand A Parekh Juan F Agudelo Wade R Smith

OBJECTIVE This study was designed to describe the anatomic insertion point of the deltoid to the proximal humerus. DESIGN Gross anatomic study. SETTING Level one academic trauma center. PATIENTS Cadaveric study. MAIN OUTCOME MEASUREMENTS Bilateral humeri were stripped of soft tissue except the deltoid insertion point. The length of the humeri was recorded. The distance from the greater ...

2011
Mee-Kyoung Son Hyun-Seon Jang

PURPOSE The emergence profile concept of an implant restoration is one of the most important factors for the esthetics and health of peri-implant soft tissue. This paper reports on two cases of gingival recontouring by the fabrication of a provisional implant restoration to produce an optimal emergence profile of a definitive implant restoration. METHODS After the second surgery, a preliminar...

Journal: :General dentistry 2018
Feras Al Rezk Georgia Trimpou Hans-Christoph Lauer Paul Weigl Nadine Krockow

Soft tissue integration in the transmucosal zone of dental abutments supports the peri-implant tissues, improves esthetics, ensures soft tissue seal against microorganisms, and preserves crestal bone level. The aim of this literature review was to define the most favorable surface topography and macrodesign of the transmucosal zone of abutments to achieve optimal soft tissue seal. An electronic...

Journal: :The International journal of robotics research 2010
Sarthak Misra Kyle B. Reed Benjamin W. Schafer K. T. Ramesh Allison M. Okamura

The tip asymmetry of a bevel-tip needle results in the needle naturally bending when it is inserted into soft tissue. This enables robotic needle steering, which can be used in medical procedures to reach subsurface targets inaccessible by straight-line trajectories. However, accurate path planning and control of needle steering requires models of needle-tissue interaction. Previous kinematic m...

Journal: :Methods 2015
Christopher Z Mosher Jeffrey P Spalazzi Helen H Lu

A significant challenge to orthopaedic soft tissue repair is the biological fixation of autologous or allogeneic grafts with bone, whereby the lack of functional integration between such grafts and host bone has limited the clinical success of anterior cruciate ligament (ACL) and other common soft tissue-based reconstructive grafts. The inability of current surgical reconstruction to restore th...

Amirreza Hendi, Mehran Falahchai, Yasamin Babaee Hemmati, Yousef Jahandideh,

 Dental implants, as a result of their excellent success rates and advantages over fixed or removable methods, have become the optimal treatment for replacing missing teeth. Surgical and restorative techniques that can reduce the loss of hard and soft tissues that often accompany implant placement are desirable. Achieving an esthetic outcome in tooth replacement and implant treatment requires a...

Journal: :Clinical oral implants research 2011
Eriberto Bressan Gianluca Paniz Diego Lops Boris Corazza Eugenio Romeo Gianantonio Favero

PURPOSE The aim of this clinical research on implant-supported restorations is to analyze, through spectrophotometric digital technology, the influence of the abutment material on the color of the peri-implant soft tissue. MATERIAL AND METHODS Twenty patients received an endosseous dental implant in the anterior maxilla. At the time of each definitive prosthesis delivery, an all-ceramic crown...

2016
Michael Polanco Sebastian Bawab Hargsoon Yoon

The functional longevity of a neural probe is dependent upon its ability to minimize injury risk during the insertion and recording period in vivo, which could be related to motion-related strain between the probe and surrounding tissue. A series of finite element analyses was conducted to study the extent of the strain induced within the brain in an area around a neural probe. This study focus...

2002
Simon P. DiMaio Septimiu E. Salcudean

A methodology for estimating the force distribution that occurs along a needle shaft during insertion is described. An experimental system for measuring planar tissue phantom deformation during needle insertions has been developed and is presented. A two dimensional linear elastostatic material model, discretised using the Finite Element Method, is used to derive contact force information that ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید