نتایج جستجو برای: stereo radiography eos thermoluminescent dosimeter tld
تعداد نتایج: 43006 فیلتر نتایج به سال:
background: eos is a 2d/3d muscle skeletal diagnostic imaging system. the device has been developed to produce a high quality 2d, full body radiographs in standing, sitting and squatting positions. three dimensional images can be reconstructed via stereos software. this health technology assessment study aimed to investigate efficacy, effectiveness and cost-effectiveness of new emerged eos imag...
Noting an increase in demand for procedures involving clinical radiosurgery we seek to develop a high spatial resolution thermoluminescence dosimeter (TLD) allow conduct of vivo dose verification measurements. An associated need is dynamic range exceeding that the well-established LiF (Mg,Ti) phosphor TLD-100, with particular latter being limited performance at elevated doses seen radiotherapy....
nowadays, radiography is a necessary procedure in diagnosis and treatment of patients with dental problems. according to the alara (as low as reasonably achievable) principle, dentists must take radiographs of sufficient quality at the lowest possible radiation dose to the patients. the assessment of patient dose on panoramic radiography is difficult because of dynamic nature of the imaging pro...
The accuracy of the photon convolution/superposition dose algorithm employed in a commercial radiation treatment planning system was evaluated for conditions simulating tangential breast treatment. A breast phantom was fabricated from machineable wax and placed on the chest wall of an anthropomorphic phantom. Radiographic film was used to measure the dose distribution at the axial midplane of t...
The application of ionizing radiations in different fields requires the use of equipment capable of detecting their presence or quantifying them. Detectors of the most different shapes, composition and characteristics are required to cover the full range of application of ionizing radiations. At present, thermoluminescent detectors (TLD) are the most widely employed for individual gamma monitor...
Introduction Radiotherapy is regarded as the first treatment of choice for nasopharyngeal carcinoma. Despite the advantages of radiotherapy, patients may suffer from a wide range of side-effects due to the presence of many sensitive normal tissues in these regions. If the absorbed dose exceeds the tolerance level in parotid glands and the spinal cord, myelopathy, Lhermitte's sign and xerostomia...
PURPOSE To design, construct, and evaluate an anthropomorphic phantom for evaluation of intensity-modulated radiation therapy (IMRT) dose planning and delivery, for protocols developed by the Radiation Therapy Oncology Group (RTOG) and other cooperative groups. METHODS AND MATERIALS The phantom was constructed from a plastic head-shaped shell and water-equivalent plastics. Internal structures...
This study is the first to use 10- to 90-kg tissue-equivalent phantoms as patient surrogates to measure peripheral skin doses (Dskin) in lung cancer treatment through Volumetric Modulated Arc Therapy of the Axesse linac. Five tissue-equivalent and Rando phantoms were used to simulate lung cancer patients using the thermoluminescent dosimetry (TLD-100H) approach. TLD-100H was calibrated using 6 ...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید