نتایج جستجو برای: suspended stripline

تعداد نتایج: 21978  

1995
W. K. Lau M. H. Wang K. T. Hsu L. H. Chang

Longitudinal coupled-bunch instabilities in the SRRC 1.3 GeV storage ring have been studied by analyzing the signals picked up from the stripline electrodes and rf power reflected from the cavities. The current dependence of the instability strengths was measured. As a cross check, the bunch phase jitters as a function of beam current has also been measured by using sampling optical oscilloscop...

Journal: :The Journal of chemical physics 2008
A P M Kentgens J Bart P J M van Bentum A Brinkmann E R H van Eck J G E Gardeniers J W G Janssen P Knijn S Vasa M H W Verkuijlen

The predominant means to detect nuclear magnetic resonance (NMR) is to monitor the voltage induced in a radiofrequency coil by the precessing magnetization. To address the sensitivity of NMR for mass-limited samples it is worthwhile to miniaturize this detector coil. Although making smaller coils seems a trivial step, the challenges in the design of microcoil probeheads are to get the highest p...

2010
R. W. Lemke M. D. Knudson J-P Davis

The intense magnetic field generated by the Z accelerator at Sandia National Laboratories is used as a pressure source for material science studies. A current of ∼20 MA can be delivered to the loads used in experiments on a time scale of ∼100e600 ns. Magnetic fields (pressures) exceeding 1200 T (600 GPa) have been produced in planar configurations. In one application we have developed, the magn...

2000
B. R. Poole

The DARHT-II beamline utilizes a fast stripline kicker to temporally chop a high current electron beam from a single induction LINAC and deliver multiple temporal electron beam pulses to an x-ray converter target. To obtain a high quality radiographic measurement requires that high beam quality be maintained throughout the transport line from the end of the accelerator through the final focus l...

2000
REUVEN SHAVIT

An analytical design method applicable to linear transverse slot arrays fed by a boxed stripline is developed. An integral equation involving the unknown electric field distribution in the slot is formulated. The method of moments is utilized to obtain a numerical solution for the field distribution. The insight gleaned from 'such a computation is used to approximate the field in the slot by a ...

1999

LLE Review, Volume 78 97 Laser-fusion experiments require precise control of the temporal profile of optical pulses applied to targets. An optical pulse– shaping system has been in operation on OMEGA for several years.1 During this time the demands on the precision, flexibility, and repeatability of the optical pulse–shaping system have steadily increased. To meet these new demands, a new pulse...

2000
S. S. Kurennoy

A new current structure for the fast traveling-wave 2.5MeV beam chopper in the front end of the Spallation Neutron Source (SNS) has been suggested in [1]. The structure is based on the meander-folded notched stripline with dielectric supports and separators. Its design has been optimized using electromagnetic 3-D modeling with the MAFIA code package to provide rise and fall times in the range o...

Journal: :Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment 2016

2001
Brian R. Poole Yu-Jiuan Chen

The DARHT-II beam line utilizes a fast stripline kicker to temporally chop a high current electron beam from a single induction LINAC and deliver multiple temporal electron beam pulses to an x-ray converter target. High beam quality needs to be maintained throughout the transport line from the end of the accelerator through the final focus lens to the x-ray converter target to produce a high qu...

Journal: :Medical physics 2010
Stephan Orzada Stefan Maderwald Sophia L Göricke Nina Parohl Susanne C Ladd Mark E Ladd Harald H Quick

PURPOSE Magnetic resonance imaging (MRI) of rodents can be expected to be a growing application, particularly when translatory imaging research "from mouse to man" is envisioned. 7 T high-field human whole-body MR systems provide a powerful platform for high-resolution small animal imaging. For achieving adequate spatial resolution, dedicated radiofrequency coils have to be designed to provide ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید