نتایج جستجو برای: tapered member

تعداد نتایج: 97094  

Journal: :Journal of biomechanics 2003
Dinçer Bozkaya Sinan Müftü

In evaluation of the long-term success of a dental implant, the reliability and the stability of the implant-abutment interface plays a great role. Tapered interference fits provide a reliable connection method between the abutment and the implant. In this work, the mechanics of the tapered interference fits were analyzed using a closed-form formula and the finite element (FE) method. An analyt...

2015
Muhamad Ramdzan Buyong Farhad Larki Mohd Syafiq Faiz Azrul Azlan Hamzah Jumrail Yunas Burhanuddin Yeop Majlis

In this work, the dielectrophoretic force (F(DEP)) response of Aluminium Microelectrode Arrays with tapered profile is investigated through experimental measurements and numerical simulations. A standard CMOS processing technique with a step for the formation of a tapered profile resist is implemented in the fabrication of Tapered Aluminium Microelectrode Arrays (TAMA). The F(DEP) is investigat...

2015
S. Priyadharshini R. Ponalagusamy

An analysis of blood flow through a tapered artery with stenosis and dilatation has been carried out where the blood is treated as incompressible Herschel-Bulkley fluid. A comparison between numerical values and analytical values of pressure gradient at the midpoint of stenotic region shows that the analytical expression for pressure gradient works well for the values of yield stress till 2.4. ...

2014

In this thesis we explore a novel technique to fabricate sub-micron diameter tapered fibers for sensor applications. Physically the light propagating in a tapered fiber has an evanescent field that extends into the medium surrounding the fiber containing an analyte. A sub-micron diameter taper can expels most the electromagnetic energy into the medium thus increasing the sensitivity of the meas...

Journal: :Medicina oral, patologia oral y cirugia bucal 2007
Mercedes Pérez Heredia Javier Clavero González Carmen María Ferrer Luque María Paloma González Rodríguez

AIM To compare the apical sealing in mesio-buccal canals of extracted molars obturated with low-temperature thermoplasticized gutta-percha or cold lateral condensation techniques using a .06 or a .02 mm/mm tapered gutta-percha master cone. The secondary aim was to evaluate the depth of spreader penetration in root canals using a .06 or a .02 mm/mm tapered gutta-percha master cone. METHODOLOGY...

2008
Dmitri K. Gramotnev Michael W. Vogel Mark I. Stockman

Using rigorous numerical methods of analysis, this paper investigates nonadiabatic nanofocusing in tapered nanorods with the major emphasis on structural optimization for achieving maximal possible local field enhancement. Simple analytical equations for the determination of the optimal length of the tapered rod are presented and discussed. It is also shown that for the considered structures, o...

Journal: :Optics express 2011
André Müller Deepak Vijayakumar Ole Bjarlin Jensen Karl-Heinz Hasler Bernd Sumpf Götz Erbert Peter E Andersen Paul Michael Petersen

Up to 16 W output power has been obtained using spectral beam combining of two 1063 nm DBR-tapered diode lasers. Using a reflecting volume Bragg grating, a combining efficiency as high as 93.7% is achieved, resulting in a single beam with high spatial coherence. The result represents the highest output power achieved by spectral beam combining of two single element tapered diode lasers. Since s...

Journal: :Optics express 2013
Davor Ristić Alphonse Rasoloniaina Andrea Chiappini Patrice Féron Stefano Pelli Gualtiero Nunzi Conti Mile Ivanda Giancarlo C Righini Gilles Cibiel Maurizio Ferrari

Coatings of spherical optical microresonators are widely employed for different applications. Here the effect of the thickness of a homogeneous coating layer on the coupling of light from a tapered fiber to a coated microsphere has been studied. Spherical silica microresonators were coated using a 70SiO(2)- 30HfO(2) glass doped with 0.3 mol% Er(3+) ions. The coupling of a 1480 nm pump laser ins...

2017
Lujia Zou Shanhua Mao Shenghua Liu Limin Zhang Tian Yang Yun Hu Qiang Ding Haowen Jiang

BACKGROUND Reconstruction of ureteral defects and strictures remains problematic for urologists. We aimed to investigate the possibility of a tapered non-vascularized bladder graft as a novel substitute for ureteral reconstruction. METHODS This experimental study was conducted on nine beagles. Under general anesthesia, a full-thickness graft with 5-6 cm in length was disassociated from the an...

Journal: :The International journal of oral & maxillofacial implants 2015
Joseph Yk Kan Phillip Roe Kitichai Rungcharassaeng

PURPOSE Primary implant stability is critical to achieving implant success, especially in a situation with immediate implant placement and provisionalization (IIPP) when bone quality and quantity are compromised. The purpose of this study was to examine the effects of implant morphology (tapered vs cylindric) and the final drill-implant diameter discrepancy (FD-IDD) of six implant systems on th...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید