نتایج جستجو برای: tube complications

تعداد نتایج: 276845  

Journal: :Arquivos brasileiros de oftalmologia 2008
Gisele Scholte de Souza Vieira Maria Emília Xavier

PURPOSE To analyze the success rate and complications in patients with lacrimal obstruction submitted to surgeries. METHODS The data of patients operated in the "Hospital do Servidor Público Estadual of São Paulo" were analyzed. The lacrimal intubation was performed with a silicone tube, removed after 8 weeks. Surgeries were considered successful in those cases where patients had no postopera...

2015
H. G. Vinay Mohammed Raza G. Siddesh

INTRODUCTION Routinely postoperative nasogastric decompression was done until the nasogastric drainage is minimal, reoccurrence of bowel sounds and passing flatus. But prolonged nasogastric intubation is associated with complications like basal atelectasis due to poor cough reflux, loss of electrolytes and increased patient morbidity. AIMS AND OBJECTIVES To study the need for routine use of n...

Journal: :Radiographics : a review publication of the Radiological Society of North America, Inc 2012
Sushilkumar K Sonavane Christine O Menias Kartikeya P Kantawala Alampady K Shanbhogue Srinivasa R Prasad John C Eagon Kumaresan Sandrasegaran

Laparoscopic adjustable gastric banding (LAGB) is performed with increasing frequency for the management of morbid obesity. Although LAGB is less invasive than other bariatric surgical procedures, it is associated with various complications that may lead to nonspecific abdominal symptoms several months or years after the procedure. Because complications of LAGB may be encountered incidentally a...

Journal: :Clinical radiology 2016
M J Kim J H Shin J-H Park J H Kim H-Y Song J Park Y C Cho S H Kim

AIM To evaluate the technical feasibility and safety of covered airway stent placement for malignant tracheobronchial strictures in patients with an endotracheal tube. MATERIALS AND METHODS Data regarding retrievable, expandable, metal stent placement under fluoroscopic guidance in 20 patients with an endotracheal tube inserted for malignant tracheobronchial strictures were retrospectively an...

2010
Ali-Akbar Sabermoghaddam Setareh Sagheb Hosseinpoor

Herein we report our experience with a simple technique for reducing the rate of silicone tube extrusion after nasolacrimal duct (NLD) intubation for congenital NLD obstruction. Medical records of children older than 2 years, with or without history of failed probing, who had undergone NLD intubation with a Crawford silicone tube over a period of 4 years were reviewed. In all subjects, one end ...

Journal: :Archives of disease in childhood 2002
P Godbole G Margabanthu D C Crabbe A Thomas J W L Puntis G Abel R J Arthur M D Stringer

BACKGROUND Gastrostomy feeding is a well established alternative method to long term nasogastric tube feeding. Many such patients have gastro-oesophageal reflux (GOR) and require a fundoplication. A transgastric jejunal tube is an alternative when antireflux surgery fails, or is hazardous or inappropriate. AIMS To review experience of gastrojejunal (G-J) feeding over six years in two regional...

2016
Qiaoya Li Juan Xie Jinxing Wu Rui Guo Wenwen Ma Gang Xu Min Yang Huisheng Deng

Background. Conventional nasogastric tube placement is an essential clinical procedure; however, complications may arise from blind manipulation. We tested the feasibility and efficiency of a visual nasogastric tube insertion system (VNGS) using a manikin. Methods. A microimaging fiber (0.8 mm) was integrated into the nasogastric tube to create the VNGS. Twenty inexperienced physicians were enr...

2012
Vijayraj Patil Abhishek Vijayakumar M. B. Ajitha Sharath Kumar L

Aim. Loop ileostomy has high complication rates and causes much patient inconvenience. This study was performed to compare the outcome of tube versus loop ileostomy in management of ileal perforations. Patients and Methods. From July 2008 to July 2011, all patients with ileal perforation on laparotomy where a defunctioning proximal protective loop ileostomy was considered advisable were chosen ...

Journal: :Endoscopy 2010
J U Lim H P Shin J I Lee J M Cha K R Joo

for replacement of a percutaneous endoscopic gastrostomy (PEG) tube. He had originally undergone PEG tube placement at our hospital 2 years ago, and after insertion the position of the hub had been checked by gastroscopy. However, placement of the most recent PEG tube had been done at another hospital 1 year ago, with no gastroscopic evaluation. When the patient attended our hospital 1 year lat...

Journal: :مجله دانشکده پزشکی دانشگاه علوم پزشکی تهران 0
بهرام ملکوتی b malakooti جلال مهدی زاده j mahdizadeh سروش امانی گشنیگانی s amani gashnigani شاهین فتح سامی sh fathsami

chronic otitis media is a common disease which can lead to serious complications or even death. betterment of eustachian tube function is effective on results of operations. the main goal of this study was to determine the effect of eustachian tube function on outcome of graft in tympanoplasty or tympanomastoidectomy for chronic otitis media. we prospectively studied 126 patients who underwent ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید