نتایج جستجو برای: vanadium alloy

تعداد نتایج: 59600  

Journal: :International journal of innovative engineering applications 2021

In this study, based on designed Ti-50Ni, Ti-27Ni-23Nb, and Ti-27Ni-19Nb-4X (Ta V) SMAs were prepared using arc melting. The microhardness microstructure of the alloys examined. optical microscope (OM) Scanning Electron Microscopy (SEM) images can be noted that Nb, Ta, V addition in substitution to nickel causes a change morphology TiNi Shape Memory Alloy at room temperature. results shown when...

Journal: :MATEC web of conferences 2022

Current research is focused on development of β-type titanium alloys for biomedical applications as substitutes the undesirable Ti6Al4V alloy. alloy has a higher elastic modulus (110 GPa) than that human bone (10-30 and this mismatch in moduli can cause stress shielding effect, which resorption implant failure. Moreover, dissociation vanadium aluminium long term diseases including Alzheimer, ne...

Journal: :Journal of inorganic biochemistry 1988
S Lee K Kustin W E Robinson R B Frankel K Spartalian

The magnetic properties of intact and freeze-dried blood cells of the tunicate Ascidia nigra and of model vanadium(III) and (IV) compounds as polycrystalline solids and in aqueous solution have been measured up to 50 kOe with a SQUID susceptometer. Corrections for the samples' diamagnetism were extracted from the temperature dependence of the data without any further assumptions. For vanadium(I...

Journal: :ACS applied electronic materials 2022

We report on a two-dimensional (2D) V1–xPtxSe2 alloy that exhibits ferromagnetic order and Rashba spin–orbit coupling. Although ferromagnetism is absent in 1T-VSe2 because of the competition with charge density wave phase, we demonstrate theoretically experimentally substitution vanadium by platinum VSe2 (10–50%) to form homogeneous 2D restores down one monolayer V0.65Pt0.35Se2. Moreover, prese...

Journal: :Journal of environmental monitoring : JEM 2006
B Gummow J van den Broek W F A Kirsten C J Botha J P T M Noordhuizen J A P Heesterbeek

Various potential biomarkers were sampled for vanadium every 3-4 months from Bos indicus beef cattle farmed extensively immediately adjacent (high exposure (HE) group) and two km away (low exposure (LE) group) from a vanadium processing plant, respectively. Vanadium intake (mg vanadium kg(-1) bwt d(-1)) was modelled using environmental and physiological data as inputs. The vanadium intake range...

Journal: :Chemical reviews 2004
Debbie C Crans Jason J Smee Ernestas Gaidamauskas Luqin Yang

6.1.2. Aqueous V(III) Chemistry 877 6.1.3. Oxidation State of Vanadium in Tunicates 878 6.1.4. Uptake of Vanadate into Tunicates 879 6.1.5. Vanadium Binding Proteins: Vanabins 879 6.1.6. Model Complexes and Their Chemistry 880 6.1.7. Catechol-Based Model Chemistry 880 6.1.8. Vanadium Sulfate Complexes 881 6.2. Fan Worm Pseudopotamilla occelata 883 7. Vanadium Nitrogenase 883 7.1. Nitrogenases 8...

Journal: :The Biochemical journal 1989
J M Arber B R Dobson R R Eady S S Hasnain C D Garner T Matsushita M Nomura B E Smith

Vanadium K-edge X-ray-absorption spectra were collected for samples of thionine-oxidized, super-reduced (during enzyme turnover) and dithionite-reduced VFe-protein of the vanadium nitrogenase of Azotobacter chroococcum (Acl*). Both the e.x.a.f.s and the x.a.n.e.s. (X-ray-absorption near-edge structure) are consistent with the vanadium being present as part of a VFeS cluster; the environment of ...

1998
Carl Johan Rydh

Ž . The environmental impact of both the vanadium redox battery vanadium battery and the lead-acid battery for use in stationary applications has been evaluated using a life cycle assessment approach. In this study, the calculated environmental impact was lower for the vanadium battery than for the lead-acid one. The net energy storage efficiency of the vanadium battery was greater due to lower...

Journal: :Talanta 1995
M L Córdova A Molina-Díaz M I Pascual-Reguera L F Capitán-Vallvey

Solid-phase spectrophotometry has been applied to analysis for trace amounts of vanadium. Vanadium was sorbed in a styrene-divinylbenzene-type anion-exchanger Dowex 1-X8 as a vanadium-4-(2-pyridylazo)resorcinol complex. Resin phase absorbances at 562 and 800 nm were measured directly which allowed the determination of vanadium in the range of 0.1-2.4 ng/ml with a RSD of 1.5%. The method has bee...

Journal: :British journal of industrial medicine 1989
C Missenard G Hansen D Kutter A Kremer

Biochemical and haematological profiles of workers exposed to vanadium were compared with those of non-exposed age matched subjects. A significantly positive and dose related correlation between serum vanadium and zinc protoporphyrin (ZPP) was observed. Normal lead concentrations excluded this heavy metal as a possible cause. Inhibition of the reduction of Fe to Fe++ by vanadium is discussed as...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید